17
Troubleshooting Guide
Problem
Possible Cause
Solution
Notes
Unit Runs Low or Out of Water
Undersized tank for store demand
Install additional storage tank capacity
Contact Dealer
RO production is to low for store
demand
Install RO add-on head and cartridge
Contact Dealer
Upgrade from HFRO 500 to HFRO 700
Cartridge
Slow leak in the distribution line
Repair leak
The unit produced RO water slowly. A dripping leak
can prevent the tank from fi lling.
RO membrane fl ow control
improperly installed or missing
Properly install RO membrane fl ow control
Note: Reference RO cartridge change-out
instructions
System shuts down and "service"
indicator light turns on blinking
Pre-Filter plugs left hand gauge
reads less than 90
Replace Pre-Filter
—
Wait for 10-60 minutes to see if system
restarts
Low production rate
Replace RO membrane
RO membrane fouls, low
production
System shuts down and “service”
indicator light turns on solid
Pre-Filter plugs left hand gauge
reads less than 90
Replace Pre-Filter
A more frequent schedule change-out
may be needed (Refer to Challenge Water
Recommendations on page 6)
RO membrane fouls (normal
conditions)
Replace RO membrane
Check for: 1. feedwater pressure, 2. production
fl ow rate, 3. drain fl ow rate before replacing RO
membrane
Ensure drain line is not kinked or plugged.
Replace if needed.
RO membrane fouls (high feed
water hardness/TDS)
Install RO add-on head and cartridge
Contact Dealer
Install a HFRO 33% Recovery Kit
Install water softener upstream
RO membrane fouls (high particle
load in incoming water)
Install prefi lter and RO expansion heads and
cartridges
Interrupted feedwater supply
Press Reset button on top of electrical
enclosure
Reference system startup procedure
Water temperature below 50
°
F
Install RO expansion head and cartridge
Low feedwater pressure (below
30 psi)
Contact plumber to resolve problem
Reference system startup procedure once low feed
water problem is resolved
Iron or Manganese in incoming
water
Contact your dealer/distributor to install
specifi c iron or manganese reduction system
TDS of product water too low
Blend too low
Re-adjust blending valve to allow more
blending
Reference Blending Valve Adjustment
TDS of product water too high
Blend to high
Re-adjust blending valve to allow less blending
Reference Blending Valve Adjustment
TDS of product water too high with
no blending
RO membrane needs to be
replaced
Replace RO membranes
—
TDS monitor not operating
Low battery
Replace TDS monitor batteries
—
Technical Support - 1-866-990-9785
Summary of Contents for ScaleGard HP
Page 19: ...19 Notes...