Read, understand, and follow all safety information contained in these instructions prior to installation 
and use of the 3M

 Water Filtration Products ScaleGard

 HP reverse osmosis system. Retain these 

instructions for future reference.

Intended use:

The ScaleGard

TM

 HP reverse osmosis system is intended for use in 

fi

 ltering potable water and has not been evaluated for other 

uses. The product is installed at the point of use and must be installed as speci

fi

 ed in the installation instruction by a quali

fi

 ed 

professional.  

SAFETY INFORMATION

SAFETY INFORMATION

EXPLANATION OF SIGNAL WORD CONSEQUENCES

EXPLANATION OF SIGNAL WORD CONSEQUENCES

WARNING

WARNING

Indicates a potentially hazardous situation, which, if not avoided, could 
result in death or serious injury and/or property damage.

CAUTION

CAUTION

Indicates a potentially hazardous situation which, if not avoided, may 
result in minor or moderate injury and/or property damage.

 NOTICE

 NOTICE

Indicates a potentially hazardous situation, which, if not avoided, may 
result in property damage.

CAUTION

CAUTION

To reduce the risks associated with environmental contamination which, if not avoided, could result in minor or moderate injury:

• At the end of useable life, dispose of this system in accordance with applicable local regulations or laws.

To reduce the risks associated with impact which, if not avoided, could result in minor or moderate injury:

• Depressurize system as shown in manual prior to cartridge removal.

To reduce the risks associated with heavy objects which, if not avoided, could result in minor or moderate injury:

• Follow safe lifting procedures.

WARNING

WARNING

Read entire manual. Failure to follow all guides and rules could cause personal injury or property damage.

• Check with your local public works department for plumbing codes. You must follow their guidelines as you install the water fi ltration system.
• Your water fi ltration system will withstand up to 125 pounds per square inch (psi) water pressure. If your water supply pressure is higher than 80 psi, install a 
pressure reducing valve before installing the water fi ltration system.
• An approved post fi lter and tank must be used with the RO system.

To reduce the risk associated with choking:

• DO NOT allow children under 3 years of age to have access to small parts during the installation of this product.

To reduce the risk associated with the ingestion of contaminants:

• DO NOT use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certifi ed for 
cyst reduction may be used on disinfected water that may contain fi lterable cysts.

To reduce the risk associated with hazardous voltage due to an installer drilling through existing electric wiring or water pipes in the area of 
installation:

• DO NOT install near electric wiring or piping which may be in path of a drilling tool when selecting the position to mount the fi lter bracket.

To reduce the risk associated with back strain:

• Follow safe lifting procedures.

To reduce the risk of physical injury:

• All hydro-pneumatic pressurized tanks MUST have an appropriate pressure relief valve installed. Pressure relief valve must be maintained and inspected 
every 6 months. Contact a plumbing professional if you are uncertain how to select/install/maintain a pressure relief valve.

To reduce the risk associated irritation from Sodium Metabisulfi te during installation:

• Sodium Metabisulfi te (CAS 007681-57-4) is used in a 1% preservative solution within the reverse osmosis membrane.
• DO NOT put this system into service before the RO tank is fl ushed as specifi ed in the installation instructions. Wear eye and face protection during installation.
• To request an MSDS relating to this product call 203-238-8965 or visit the web at http://solutions.3m.com).  For emergencies, call 800-364-3577 or 651-
737-6501 (24 hours).

To reduce the risk associated with ingestion of water contaminaed with sanitizer:

• After installation, sanitizer MUST be fl ushed from the system before fi rst use as directed within the installation instructions.

SAFETY INFORMATION CONTINUED ON NEXT PAGE

IF CONNECTION IS MADE TO A POTABLE WATER SYSTEM, THE SYSTEM SHALL BE PROTECTED AGAINST BACKFLOW.

Summary of Contents for ScaleGard HP

Page 1: ...manual with owner operator Owner Operator Please retain for operation and future instructions 3M Water Filtration Products Installation and Operation Instructions for ScaleGardTM HP Reverse Osmosis S...

Page 2: ...aution Statements 4 Parts List 5 Feedwater Requirements 6 Other Requirements 6 Equipment Set Up and Installation 7 System Start Up 10 Routine Maintenance 15 16 Troubleshooting Guide 17 Product Replace...

Page 3: ...is higher than 80 psi install a pressure reducing valve before installing the water filtration system An approved post filter and tank must be used with the RO system To reduce the risk associated wit...

Page 4: ...T install an appropriate pressure relief valve Pressure relief valve must be maintained and inspected every 6 months Contact a plumbing professional if you are uncertain how select install maintain a...

Page 5: ...ilter and RO with UK plug 6239304 220 240VAC w out Pre filter and RO with AU plug HF90 CL RO Pre Filter 1 5613529 HFRO 500 RO membrane 1 5626903 Equipment Components Sold Separately Description Quanti...

Page 6: ...PN 50 93201 If the particle count is 1000 counts ml for particles less than 2 micron size or turbidity is greater than the recommended 5 ntu limit then it may be required to consider different prefilt...

Page 7: ...leGard HP reverse osmosis base unit and 0 5 or larger tubing diameter is required to complete installation Figure 1 Plumbing Diagram Bypass Provided by Installer Check Valve Provided by Installer 1 2...

Page 8: ...with property damage due to water leakage or flooding Mount ScaleGardTM HP base unit in such position as to prevent it from being struck by other items being used in the area of installation Ensure t...

Page 9: ...Plumbing connections for the ScaleGardTM HP reverse osmosis system are now complete Install cartridge per instructions below Pre Filter and Post Filter Cartridge blue label Installation 1 Remove red s...

Page 10: ...ee Figure 1 page 7 2 Turn ON the feedwater supply by plugging system into electrical outlet 3 Open Pre Filter flush valve to vent air from system and flush for 10 gallons approximately 5 minutes If er...

Page 11: ...after the desired TDS value is reached Re adjust and check as needed See Figure 5 item 2 below 4 Lock the blending valve using the lock nut 5 After TDS is set drain RO tank System is now ready for use...

Page 12: ...BLUE BROWN Step Down Transformer 3 WIRE NUT 8 LEVER NUT 14 11 6 LEVER NUT 5 LEVER NUT 7 LEVER NUT TERMINAL BLOCK Output LED Color Meaning Normal Running Condition PWR Green On when the units power co...

Page 13: ...bar for 220 240VAC systems the unit is off on full tank 1 Unit will cycle on when tank switch senses 40 psi TOGGLE CYCLE 1 Motor Pump stop 2 2 second delay the inlet solenoid closes 3 1 second delay t...

Page 14: ...is is normal To reduce the risk associated with property damage due to water leakage or flooding Notice Take care when using pliers or pipe wrenches to tighten plastic fittings as damage may occur if...

Page 15: ...low their guidelines as you install the water filtration system Your water filtration system will withstand up to 125 pounds per square inch psi water pressure If your water supply pressure is higher...

Page 16: ...pressure 2 Release tubing 3 Cut off at least 1 4 from end 4 Reattach tubing 5 Confirm connection is leak free Figure 9 How to Use Push in Connectors 4 Remove sanitary cap from new RO membrane cartridg...

Page 17: ...e Check for 1 feedwater pressure 2 production flow rate 3 drain flow rate before replacing RO membrane Ensure drain line is not kinked or plugged Replace if needed RO membrane fouls high feed water ha...

Page 18: ...ge Contact Dealer 60 125001 Permeate Solenoid Contact Dealer 85 9274 Shroud Contact Dealer 89 3220101 Pump Head Contact Dealer 89 2302 Pump Motor Contact Dealer 5613529 HF90 CL RO Pre Filter 5626903 H...

Page 19: ...19 Notes...

Page 20: ...1 year from the date of purchase The filter cartridge or membrane is warranted to be free from defects in material and manufacture for one 1 year No warranty is given as to the service life of any fi...