Troubleshooting (continued)
Condition 1:
Applicator
will not heat
b. Using the ohmmeter, check for continuity between terminal
number 2 (white wire from cord) on the lower terminal block
TB1 and the AC neutral terminal on the applicator plug
(see Figures T and U).
If the measurements in a) or b) above indicate electrical
discontinuity in the cord, the cord is defective. Replace the
power cord by ordering 3M™ Power Cord Kit
#62-9680-9920-0.
If the measurements in a) and b) above verify electrical
continuity, then the power cord is functioning properly.
16. The cause of the heating problem has now been isolated to be the
temperature controlling circuit. Replace the temperature
controlling circuit by ordering 3M™ Handle/Controller Kit
#62-9680-9732-9.
AC Line Terminal
AC Neutral Terminal
Figure U