© 3M 2006
6
Operation
Changing Tips
Caution
Contact with molten adhesive or hot applicator tip or
metal components may cause burns. Wear heat-
resistant gloves and safety glasses when operating or
repairing the 3M™ Scotch-Weld™ Hot Melt
Applicator PG II LT.
The 3M Scotch-Weld Hot Melt Applicator PG II LT
includes a 9921 (.093’’) tip as standard equipment.
Other tips, available from your 3M Scotch-Weld Hot
Melt Adhesive distributor, are shown on page 22 of
this manual.
Note
Disconnect air supply before changing tips.
Tips can be changed only when the applicator is
hot.
You will need a 5/8’’ and a 1/2’’ open-end
wrench. Hold the nozzle valve hex firmly with the
5/8’’ wench, while removing the nozzle tip with the
1/2’’ wrench. The accessory tip is mounted using the
reverse procedure. Snug the tip lightly.
Note
Do not tighten the tip. Overtightening could
damage the valve assembly.
!