background image

5

78-8135-7466-8-B

6.3 

Using the supplied hose clamp, secure cables to the 

cable addition bracket and cable management tray 

frame as shown. Tighten hose clamp between 25 to 

30 in.-lbs. (2.9 to 3.5 kgf-m).

6.4 

If a single cable entry is also employed through 

second endseal port, please refer to instruction 

manual number 78-8135-4502-3 for cable installation 

section 4.0. 

Summary of Contents for SLiC 530

Page 1: ...11 78 8135 7466 8 B 3 3M SLiC 530 533 733 2 Port 0 61 Cable Entry Bracket 3M SLiC 530 533 733 2 Port MSM 0 61 Cable Entry Bracket For use with 3M SLiC Free Breathing Fiber Optic Closures and Terminals Instructions ...

Page 2: ...Instruction Manual 78 8128 0289 6 Not Shown A B C D E F G H 2 0 Cable Preparations 2 1 Per company practice remove sufficient cable jacketing to allow for slack storage and splicing needs approximately 5 feet 2 2 Trim central strength members on both cables approximately 3 76 mm from the end of the cable jacket Note When using ribbon fiber cable leave a minimum of 2 50 mm of central tube 2 3 Inser...

Page 3: ... step 3 2 Remove central strength member retainer Unscrew and remove the central strength member retainer that is intended for use If installed using rivets do not perform this step 3 3 Loosen the second screw just enough to allow the cable addition bracket to slide under the CSM retainer Replace the screw that was removed previously and tighten the shield bond connector tightening fastener betwee...

Page 4: ...ing the 3M Scotchlok Shield Bond Connector 4460 D FO 5 1 Please refer to instruction 78 8128 0289 6 3M Scotchlok Shield Bond Connector Assembly 4460 D FO and 4460 D FO SS for installation instructions 6 0 Installation into Closure or Terminal 6 1 Assembly is now ready to place in the end seal of the closure or terminal Refer to instruction manual number 78 8135 4502 3 for end seal installation 6 2...

Page 5: ...addition bracket and cable management tray frame as shown Tighten hose clamp between 25 to 30 in lbs 2 9 to 3 5 kgf m 6 4 If a single cable entry is also employed through second endseal port please refer to instruction manual number 78 8135 4502 3 for cable installation section 4 0 ...

Page 6: ...of 3M Warranty Limited Remedy Limited Liability This product will be free from defects in material and manufacture for a period of one 1 year from the time of purchase 3M MAKES NO OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE If this product is defective within the warranty period stated above your exclusive remedy shall b...

Reviews: