78-8122-3169-0-F
19
7.3 Method 3 – 3M
™
Flexible Port Entry Kit 4297-FPE
Materials required:
• 3M
™
Flexible Port Entry Kit 4297-FPE
• 3M
™
Scotchcast
™
Pedestal Base Sealant Kit 4411B
Note: This option is used when several cables enter
into the cabinet. It uses a large, open cable port and is
sealed with 3M
™
Foam Tape 4430 and 4411 expanding
sealant.
a)
Replace top access panel using supplied
fasteners and self-tapping screws.
b)
Replace front access panel using supplied
fasteners.
c)
Attach foam seal across front of cabinet.
+ Long Pan
d)
Remove factory installed black ports from the
cabinet.
e)
Remove the front plate from the flexible
port entry kit. Install the port body onto the
threaded studs.
f)
Place cables into port and install the front plate.
Wrap each cable with at least one layer of foam
tape. Leave 1/2" of space between the top of
the tape and top of the port. Install base cover
plate. Tighten all bolts.
g)
Mix the expanding sealant according to
manufacturer's instructions.
Note: Carefully follow safety, health and environmental
information given on product label or the Material
Safety Data Sheet for the compound being used.
h)
Pour 3M
™
Scotchcast
™
Pedestal Base Sealant
4411 1/8" thick on top of the foam tape and
ensure that the material surrounds the cables
and creates a seal. Allow space for foam to
expand.
i)
Allow foam to harden, usually 10 minutes,
then continue with splicing.