Remove module securement screw. Lever bottom edge of reader module
away from the backplate, and lift up.
3.
installation guide
Once the backplate is secured, make wire
connections to the reader, in accordance with
the screw terminal connections shown on
Page 3 of this document and your control panel
requirements. Ensure the cable does not impair or
prevent the reader module being secured.
i
Backplate FIXING TEMPLATE.
If printed full scale, you may use the drawing below as a
fixing template.
MEASURE and CHECK DIMENSIONS before use.
Fix reader BACKPLATE to a plain surface finish, using suitable screw
fixings having a diameter no greater than 0.15 in. (4mm).
Fasten the reader module, ensuring the top-edge fixing lugs engage
correctly with the recesses at the top of the backplate. Swing the bottom
edge of the module down and forward until you feel the unit ‘snap’ shut.
i
Following installation, it is recommended the access
control system and control units are subjected to a
maintenance and operational test procedure.
TEST COMPLETE SYSTEM AT LEAST ONCE A YEAR
1
2
3
4
5
Secure the module to the backplate using the M3x10mm screw supplied.
If required, you may opt to use a security screw to the sizes shown here.
i
Mounting this reader on (or near) metal may impair the read
range of the unit.
2.7 in.
(65mm)
1.4 in.
(34.4mm)
1.9 in.
(49mm)
0.5 in.
(13mm)