background image

BASIC  TROUBLESHOOTING 

Mains power generates interferences because of  numerous parallel  connected  appliances and 

devices  (motors,  spot  lights, fluorescent lighting,  etc . . .  

The  behaviors of  metal frames  or guide bars  sometimes like  resonance circuits tuned to  the system 
frequency. 

Install antennas remotely from  these structures or fit  bonding  braids  in  order to  cancel  resonance 

phenomena. 

In case  of implementing  problems because of the site  configuration,  perform  testing  in  order to 

determine the best  location. 

Avoid  installing antennas to  close to  such  metallic masses while keeping  to  a  minimum distance of 40 

cm  away from  antenna. 

Metallic masses generate interference because of system  absorbed  and  reverberated 

electromagnetic waves. 

A number of switching  power supplies as  used for example,  in  Electronic  Information  Systems  (EIS) 

operate at  a  harmonic frequency similar to  that of the  EAS  system  and  may cause system jamming. 
Therefore,  under no circumstances should the  power supply unit be  connected  to  a  line backed  up by 
an  Uninterrupted  Power Supply (UPS) (rectified  current). 

and therefore,  a dedicated  line shall be 

provided  directly from  the switching  board.  This  line shall  be  installed  by  an  approved  installer. 

)  

INTERFERENCE SOURCES 

Steel  frames of doors sometimes behave  in  the same  manner.  Install antennas remotely from  such 

structures or fit shunts or bonding  braids  in  order to  cancel  resonance phenomena. 

Position the system  away from  steel frame doors

then open  and close doors and check the 

DC  Noise 

level 

for evidence of distorted  signals (tag  signal). 

Defective fluorescent lighting

e . g .   neon type

generates  interference  because of permanent DC 

energizing on  switching  on.  Please feel  free  to  have this type  of  lighting switched  off and compare 
results with  the 

DC  Noise level. 

Some transformers  use  in  this type  of lighting  appliances may  be 

defective  and cause similar interference. 

All  electromagnetic filed  generating  appliances typically  incorporate transformers

motors  or mobile 

magnets

including: fluorescent neon  tubes

halogen  quartz bulbs

cashiers conveyor belts

etc. 

Power leads may also  be  a  cause for  interference.  Prevent antennas from  standing too close to 

electrical  leads.  Move  antennas and  perform  various tests to  assess the best  location. 