Specification
】
Panel
100M POE copper port
10/100 Base-T(X) RJ45,
automatic flow control, full/half
duplex mode, MDI/MDI-X
autotunning, POE port,
maximum output power
consumption is 30W.
POE pins
V+, V-, V+, V- are
corresponding to 1, 2, 3, 6.
Gigabit Combo port
10/100/1000Base-T(X) or
1000Base-X
Console port
CLI command management
port (RS-232), RJ45
Alarm interface
6-pin 5.08mm pitch terminal
blocks, including 2-pin alarm
terminal blocks. It supports 1
channel relay alarm information
output, current load capacity is
1A@30VDC or 0.3A@125VAC
Indicator
Run indicator, interface
indicator power indicator, alarm
indicator, PoE indicator
Exchange attributes
Backplane bandwidth
7.6G
Packet buffer size
1Mbit
MAC table size
8K
Power supply
Input power supply
Power supply input voltage:
48VDC
Support dual power supply
redundancy, anti-reverse
Access terminal
6-pin 5.08mm pitch terminal
blocks, including 4-pin power
supply terminal blocks
Consumption
No-load
4.9W@48VDC
Full-load
122.8W@48VDC
Working environment
Working temperature
-40~75
℃
Storage temperature
-40~85
℃
Working humidity
5%~95% (no condensation)
Protection grade
IP40 (metal shell)