Notice Before Mounting: 

 

Don't place or install the device in area near water or 
moist, keep the relative humidity of the device 
surrounding between 5%~95% without condensation. 

 

Before power on, first confirm the supported power 
supply specification to avoid over-voltage damaging the 
device.

 

 

The device surface temperature is high after running; 
please don't directly contact to avoid scalding. 

Wall-mounted Device Mounting

 

Step 1 

On the wall of device mounting, place the device on 
the wall for reference or refer to the mounting 
dimension to mark two screw positions. 

Step 2 

Nail M4 screws on the wall and keep 2mm 
interspace reserved. 

Step 3 

Hang the device on two screws and slide 
downward, then tighten the screw to enhance 
stability, mounting ends. 

 

 

Wall-mounted Device Disassembling

 

Step 1 

Device power off. 

Step 2 

Unscrew the screw on the wall about 2mm. 

Step 3 

Lift the device upward slightly; take out the device, 
disassembling ends. 

Notice before power on:

 

 

Power ON operation: First insert the power supply 
terminal block into the device power supply interface, 
and then plug the power supply plug contact and power 
on. 

 

Power OFF operation: first unpin the power plug, then 
remove the power line, please note the operation order 
above. 

Power Supply Connection

 

This device provides 1 DC power supply which 
is 3-pin 5.08mm pitch terminal block, the power 
supply supports non-polarity. Power supply 

range: 12~48VDC. The pin definitions of the terminals are 
shown as follows: 

PIN 

Definition 

V+ 

FG 

V- 

Reset Button Setting

 

This device provides 1 reset button, press the button for 4-5S 
then release it to restore factory defaults. 

Serial Port Connection

 

This device provides 1 3IN1 serial port, 
which supports RS232, RS485 and RS422 
at the same time. The interface type is DB9 

male and its pin definitions are as follows: 

PIN 

RS-232 

RS-422 

RS-485 

T+ 

D+ 

RXD 

T- 

D- 

TXD 

R+ 

DTR 

R- 

GND 

GND 

GND 

DSR 

RTS 

CTS 

Checking LED Indicator

 

The device provides LED indicators to monitor the device 
working status with a comprehensive simplified 
troubleshooting; the detailed status of each LED is described 
in the table as below: 

LED 

Indicate 

Description 

PWR 

ON 

PWR is connected and running 
normally 

OFF 

PWR is disconnected and running 
abnormally 

RUN 

ON 

The device is powered on or the 
device is abnormal. 

OFF 

The device is powered off or the 
device is abnormal. 

Blinking 

Blink once per second, device is 
running normally. 

LINK 

ON 

Copper port has established an 
active network connection. 

Blinking 

Copper port is in a network activity 