background image

Insert a little to the bottom, lift upward and then insert 

to the top. 

 

Check and confirm the product is firmly installed on 

Step 3

DIN-Rail, and then mounting ends. 

Disassembling DIN-Rail

 

 

Power off the device. 

Step 1

 

After lift the device upward slightly, first shift out the 

Step 2

top of DIN-Rail mounting kit, and then shift out the 

bottom of DIN-Rail, disassembling ends. 

Attention before powering on: 

 

Power ON operation: first connect power line to the 

connection terminal of device power supply, and then 

power on. 

 

Power OFF operation: first unpin the power plug, and 

then remove the power line, please note the operation 

order above. 

Power Supply Connection

 

 

DC power supply 

This  series  provide  3-pin  5.08  pitch  power 

input  terminal  blocks.  Power  supply  range: 

12~48VDC/24VAC 

DIP Switch Settings

 

It  provides  4-pin  DIP  switch  for  function  settings, 

among which “ON” is enable valid end. 

The definitions of DIP switch are as follows: 

DIP 

Definition 

Operation 

Loop detection 

Set the DIP switch to ON to 

enable the loop detection 

function. 

Storm suppression 

Set the DIP switch to ON to 

enable the storm 

suppression function. 

One-key VLAN 

Set the DIP switch to ON to 

enable  VLAN  function,  port 

1  can  communicate  with 

DIP 

Definition 

Operation 

other ports, while other ports 

are  isolated  from  each 

other.   

Flow control 

Set  the  switch  to  ON  to 

enable  the  flow  control 

function 

Checking LED Indicator

 

The function of each LED is described in the table as below:   

LED 

Status 

Description 

PWR 

ON 

Power supply is connected and 

running normally 

OFF 

Power supply is disconnected 

and running abnormally. 

Link/ACT 

(1-8) 

ON 

Ethernet port connection is 

active. 

Blinking 

Data transmitted 

OFF 

Ethernet port connection is 

inactive. 

Specification

 

Panel 

 

100M copper port

 

10/100Base-T(X) self-adapting 

RJ45 port, full/half duplex 

self-adaption, support 

MDI/MDI-X self-adaption

 

Indicator 

Power indicator, interface 

indicator 

Exchange attributes

 

 

Backplane bandwidth

 

1.6G

 

MAC table size

 

2K

 

Power supply

 

 

Input power supply

 

12~48VDC/24VAC 

Access terminal 

3 pins 5.08mm pitch terminal 

blocks 

Support anti-reverse connection 

and over-current protection

 

Consumption 

 

No-load

 

0.5W@24VDC 

Full-load

 

1.4W@24VDC 

Environmental Limits 

 

Working temperature

 

-40~75

 

Storage temperature

 

-40~85

 

Working humidity

 

5%~95% (no condensation)

 

Protection grade 

IP40 (metal shell)

 

MTBF 

540249 hrs 

 

Reviews: