IES618 series 

Managed Industrial Ethernet Switch   

CLI user manual

 

 

 

 

 

 

 

 

 

Version 1.0.0, Sep. 2017 

www.3onedata.com

 

 

Summary of Contents for IES618 Series

Page 1: ...IES618 series Managed Industrial Ethernet Switch CLI user manual Version 1 0 0 Sep 2017 www 3onedata com...

Page 2: ...heir respective manufacturers Agreement As the product version upgrades or other reasons this document is subject to change without notice Unless other agreement this document only as a guide to use A...

Page 3: ...Configuration 14 3 1 Port information 14 3 2 Display port configuration information 14 3 3 Port configuration 14 3 4 To enable or disable the port 15 3 5 Configure the port speed and duplex mode 15 3...

Page 4: ...iguration view 28 9 2 Ring network state information view 28 9 3 To enable or disable the ring 28 9 4 The Ring1 configuration 29 9 5 The Ring2 configuration 29 9 6 The Ring3 configuration 30 9 7 The R...

Page 5: ...configuration view 40 15 2 System timeout 40 15 3 IP address and default gateway setting 40 15 4 User name password settings 41 15 5 Display device IP subnet mask default gateway 41 15 6 Restore facto...

Page 6: ...onitoring terminal equipment One end is RJ45 eight core plug the other end is the 9 hole plug DB9 Console RJ45 the switch socket head the cable inner connecting line diagram as shown below Figure 1 1...

Page 7: ...s consistent with the port connected with the configuration cable Click OK As shown in Figure 1 1 4 Figure 1 1 4 3 Set serial port parameters As shown in Figure 1 1 5 set the Bits per second in the Pr...

Page 8: ...l attribute In the Hyper Terminal window select document property setting into the attributes settings window Select the terminal simulation of type VT100 or automatic detection click OK button to ret...

Page 9: ...e displayed 1 2 Configuration through Telnet Terminal device use telnet connect to the switch through PC the requirements are as follows 1 The IP address of the switch can get it by search or modify U...

Page 10: ...ble 1 3 1 as follow Table 1 3 1 Format Description Bold Key words of the command show by bold type italic Parameter of the command show italic type It shows part in is optical when command configurati...

Page 11: ...telligent complement with Tab when commands input 5 Command interpreter take the method of partial matching User can type in conflict free key words such as config command only need to type in conf 1...

Page 12: ...ify the bandwidth information such as the inlet and outlet bandwidth settings etc Switch Bandwidth Bandwidth IGMP Snooping Set IGMP snooping or IGMP query show MAClist Switch Igmp IGMP VLAN View or mo...

Page 13: ...ticast Filtering Show or modify static multicast address like add static multicast address Switch Multicast Multicast 1 4 2 Command lines Online help Command lines port provides the following online h...

Page 14: ...ow device type name etc 2 Partial help 1 Type in a character string with It can show all commands beginning with this character string Example Switch M Mirror dir Enter port mirror menu Manage dir Ent...

Page 15: ...ed operating please check table 1 4 4 as follows Table 1 4 4 access history command Operating Key Result Visit previous history command Up If it exists earlier command it is taken out Visit next histo...

Page 16: ...information command as table 2 2 1 Table 2 2 1 Operating Command Description Show system version show version Carry out under the view of device information Show MAC address of device show mac Carry...

Page 17: ...bytes Example Configure device name as AB123 enter the bold type command as follows and enter return key Switch information config n ABC123 OK 2 4 Delete device information Please reference table 2 4...

Page 18: ...CLI user manual 13 Example Delete Contact information enter the bold type command as follows and enter return key Switch information clean c OK...

Page 19: ...r the port configuration view Table 3 1 1 to enter the port configuration view Table 3 1 1 Operating Command Description Enter the port configuration view port In view of the system under the 3 2 Disp...

Page 20: ...scription Configure the port speed and duplex mode Mode portlist 10h 10f 100h 100f auto portlist 1 3 5 8 or all mode 10h 10Mbps Half duplex 10f 10Mbps Full duplex 100h 100Mbps Half duplex 100f 100Mbps...

Page 21: ...h In view of the system under 4 2 Egress bandwidth configuration By default the egress bandwidths not limit Table 4 2 1 Egress bandwidth configuration Table 4 2 1 Operating Command Description Egress...

Page 22: ...ion Configuratio n of type of ingress limited packets Config intype portlist 0 1 2 3 portlist 1 3 5 8 or all 0 1 2 3 Limit the packet type 0 All frames 1 Broadcast Multicast and flood unicast frames 2...

Page 23: ...CLI user manual 18 port 2 1M 2M 4M 8M port 3 unlimited unlimited unlimited unlimited...

Page 24: ...mode enable Table 5 2 1 IGMP snooping enable configuration Table 5 2 1 Operating Command Description IGMP snooping enable set Set igmp enable disable Example Switch IGMP Set igmp enable OK 5 3 IGMP qu...

Page 25: ...Table 5 5 1 Operating Command Description Check the MAC address table Show MAClist Example Switch Igmp show MAClist IGMP Snooping query time 125 seconds 1 MAC List 01 00 5E 00 00 FB Port 5 2 MAC List...

Page 26: ...l not be forwarded to the other VLAN helps to control the flow reduce equipment investment simplifying the management of network improve network security The switch supports 802 1Q VLAN and port based...

Page 27: ...CPU port typelist UnModified UnTagged Tagged Delete Vlan Delete vidlist vidlist 1 4 5 4094 or all Example add VLAN of 2 a member of the port in 2 3 4 5 6 Switch Vlan Add 2 2 3 4 U VID 2 Port_cpu port...

Page 28: ...g Command Description Pvid setting config pvid portlist pvid portlist 1 3 5 8 or all 0 CPU port pvid 1 3 5 8 or all 0 CPU port Port Type setting config type portlist Trunk Access portlist 1 3 5 8 or a...

Page 29: ...delete command Operating Command Description Add multicast address Add macaddress portlist macaddress multicast address format is XY XX XX XX XX XX X is any hex number portlist Port 1 2 3 8 or all Del...

Page 30: ...llowing command to set the Dscp Cos enabled Table 8 2 1 to DScp Cos Operating Command Description Check Tos Cos check portlist 0 1 2 3 portlist Port 1 2 3 8 0 Forbid 1 use ToS 2 use CoS 3 all use Exam...

Page 31: ...e 5 priority Medium CoS value 7 priority Low 8 5 The default port priority allocation The user can configure a default port priority to use the following command Table 8 5 1 the default port priority...

Page 32: ...CLI user manual 27 Operating Command Description To view the default port priority Show default portlist portlist port 1 2 3 8 or all...

Page 33: ...mation view Operating Command Description Enter the ring network state information view Show ring To perform the operation in the system 9 3 To enable or disable the ring Users can use the following c...

Page 34: ...guration will be validated after restarting Switch Ring config ring1 3 4 OK Tip This configuration will be validated after restarting 9 5 The Ring2 configuration User can use the following command to...

Page 35: ...enabled can use the following command to set the Ring3 Table 9 6 1 Ring3 to set and modify Operating Command Description Configuration Ring3 Config ring3 1 2 id LoopType port hellotime 1 2 3 4 1 ring...

Page 36: ...5 6 Switch Ring modify 1 p 5 6 OK Tip This configuration will be validated after restarting 9 7 The RSTP configuration RSTP enabled can use the following command to set the RSTP Table 9 7 1 RSTP to s...

Page 37: ...52 53248 57344 61440 h modify hellotime Range 1 10 s d modify delaytime Range 4 30 s m modify maxage Range 6 40 s Modify rstp_port 1 2 3 4 5 6 7 8 options parameter options c modify pathcost Range 0 2...

Page 38: ...33 Switch Ring Config rstp_port 1 20000 128 auto yes yes OK Tip This configuration will be validated after restarting Switch Ring Modify rstp _port c 30000 OK Tip This configuration will be validated...

Page 39: ...uration delete command Operating Command Description Configuration trunk Config 0 1 2 portlist 0 1 2 0 1 2 respectively mean trunk group1 2 3 portlist trunk port 1 2 3 8 or all Delete trunk Clean trun...

Page 40: ...iew Operating Command Description Show Snmp information Show To perform the operation in the system Close snmp Close Switch Snmp Show The only read community name public The read or write community na...

Page 41: ...rating Command Description Configure port alarm Port relay portlist enable disable portlist Alarm ports 1 2 3 8 or all Configuration power alarm Power relay 1 2 all enable disable 1 2 all Show the way...

Page 42: ...ow port portlist portlist Alarm ports 1 2 3 8 or all Show alarm output type Show type Run in view of alarm Example set the alarm information port Switch Alarm show port all Port 1 Alarm status Disable...

Page 43: ...rt Statistics configuration view Table 13 2 1 to enter the port statistical configuration view Operating Command Description Statistics port number and type Show frames port port 1 10 Clean up the cou...

Page 44: ...tion delete Table 14 2 1 port mirroring configuration delete command Operating Command Description Port mirroring configuration Config 0 1 mirror_port port 0 1 Data type 0 all data 1 Egress data only...

Page 45: ...can use the following command to set the system time Table 15 2 1 system timeout command Operating Command Description System timeout setting Set time_out time_out The system timeout value of 0 60 the...

Page 46: ...user name password settings Operating Command Description User name setting Hostname hostname hostname The user name string User password setting Password password password password The user password...

Page 47: ...factory settings Switch manage restore Restore Settings or not yes no yes Y Wait 15 7 The address of the DNS server settings Table 15 7 1 address of the DNS server setup command Operating Command Desc...

Page 48: ...hbors Print machine s neighbor infomation Print local Print lldp statistics local counters Clear Clear lldp statistics local counters 16 2 LLDP configuration and display Operating Command Description...

Page 49: ...lldp statistics local counters print local Clear lldp statistics local counters clear Switch Lldp show Lldp Configuration Enable Lldp Configuration of sending PDU Tx Interval 30 seconds Tx Hold 4 Tx D...