background image

spring support) into DIN-Rail. 

Tips: 
The DIN-Rail spring support is a metal sheet that can 
move up and down, and there will be a sound after it is 
clamped in. 

 

Check and confirm the product is firmly installed on 
DIN-Rail, then mounting ends. 

Disassembling DIN-Rail

 

 

 

Power off the device. 

 

Use a slot type screwdriver or other tools to move 
the DIN rail spring support downward; At the same 
time, move the lower side of the device outward 
and move out the lower part of the DIN rail 
mounting kit. 

 

Lift the device upward slightly, move out the upper 
part of DIN-Rail mounting kit. Disassembling ends. 

Notice before power on:

 

 

Power ON operation: First insert the power supply 
terminal block into the device power supply interface, 
then plug the power supply plug contact and power on. 

 

Power OFF operation: First, remove the power plug, 
then remove the wiring section of terminal block. Please 
pay attention to the above operation sequence. 

Power Supply Connection

 

 

DC power supply 

The device provides 4 pins power supply input terminal blocks 
and supports two independent DC power supply systems, 

PWR1 and PWR2, which supports non-polarity and 
anti-reverse connection function, that the device can work 
normally after reverse connection. 
Voltage range: 12~48VDC. 

Relay Connection

 

Relay terminals are a set of normally open 
contacts of the device alarm relay. They are 
open circuit in the state of normal non alarm, 
closed when any alarm information occurs. For 

example, they are closed when powered off, and send out 
alarm. The product supports 1 relay alarm information output 
that can output DC power supply alarm information or network 
abnormality alarm. It can be connected to alarm light or alarm 
buzzer or other switching value collecting devices, which can 
timely inform operators when the alarm occurs.

 

DIP Switch Settings

 

Provide 4-pin DIP switch for function setting, "ON" 
is enable valid terminal. The definitions of DIP 
switch are as follows: 

DIP 

Definition  Operation 

Restore 
Factory 
Settings 

Set the DIP switch to ON, the 
device will root automatically and 
restore to factory settings, then 
turn off the DIP switch. 

1, 3, 4 

Reserved 

Console Port Connection

 

The device provides 1 program debugging port based on 
RS232 serial port which can conduct device CLI command 
management after connecting to PC. The interface adopts 
RJ45 port, the RJ45 pin definition as follows: 

Pin No. 

Definition 

TXD 

RXD 

GND 

Checking LED Indicator

 

The device provides LED indicators to monitor its operating 

status, which has simplified the overall troubleshooting 
process. The function of each LED is described in the table 
below: 

LED 

Indicate 

Description 

P1 

ON

 

Power P1 is connected and running 
normally

 

OFF

 

Power P1 is disconnected or 
running abnormally

 

P2 

ON

 

Power P2 is connected and running 
normally

 

OFF

 

Power P2 is disconnected or 
running abnormally

 

ALM 

ON

 

Power supply or the port link is 
alarming.

 

OFF

 

Power supply, port link without 
alarm

 

RUN 

ON/OFF

 

The device is running abnormally

 

Blinking

 

Blinking 1 time per second, the 
device is running normally.

 

1-16,   
G1-G4 

ON

 

Ethernet port has established a 
valid network connection

 

Blinking

 

Ethernet port  is in an active 
network status

 

OFF

 

Ethernet port has not established 
valid network connection

 

Logging in to WEB Interface

 

This device supports WEB management and configuration. 
Computer can access the device via Ethernet interface. The 
way of logging in  to device’s configuration interface via IE 
browser is shown as below: 

 

Configure the IP addresses of computer and the 
device to the same network segment, and the 
network between them can be mutually accessed 

 

Enter device’s IP address in the address bar of the 
computer browser. 

 

Enter device’s username and password in the login 
window as shown below. 

Reviews: