Managed Industrial Ethernet Switch User Manual
3onedata proprietary and confidential 50
Copyright © 3onedata Co., Ltd.
For Device 101/102/103/104, choose “Slave” in the drop-down list of “Master-slave” of
Step 5
“Group 1”.
For Device 100, choose “Master” in the drop-down list of “Master-slave” of “Group 1”.
Step 6
Click “Apply”.
Step 7
Enter “Main Menu > System Management > Device Address”.
Step 8
In the area of “reboot the device”, click “reboot”.
Step 9
End.
Step 10
Operation Step 2: creating chain
Configuring Device 105 and 106 in the following steps respectively.
Choose “Main Menu > Redundancy > Rapid Ring”.
Step 1
In the “Settings” area of “Rapid Ring” page, choose “Ring V3” as “Protocol of
Step 2
Redundancy”.
Check the “Enable” box in the “Group 1”.
Step 3
In the “Settings” area of “Rapid Ring” page, set the “Type” to “Chain”.
Step 4
In the “Settings” area of “Rapid Ring” page, set the “ID” to “2”.
Step 5
Set “Port 1” to “02” and set “Port 2” to “03”.
Step 6