Check if the DIN-Rail mounting kit is installed firmly. 

 

Insert the bottom of DIN-Rail mounting kit (one side 
with spring support) into DIN-Rail, and then insert 
the top into DIN-Rail. 

Tips: 
Insert a little to the bottom, lift upward and then insert 
to the top. 

 

Check and confirm the product is firmly installed on 
DIN-Rail, then mounting ends. 

Disassembling DIN-Rail

 

 

Power off the device. 

 

After lifting the device upward slightly, first shift out 
the top of DIN-Rail mounting kit, and then shift out 
the bottom of DIN-Rail, disassembling ends. 

Notice before power on:

 

 

Power ON operation: First insert the power supply 
terminal block into the device power supply interface, 
then plug the power supply plug contact and power on. 

 

Power OFF operation: First, remove the power plug, 
then remove the wiring section of terminal block. Please 
pay attention to the above operation sequence. 

Power Supply Connection

 

The device provides 6-pin 5.08mm pitch terminal blocks and 
power supply occupies the left 4 pins. It supports two 

independent DC power supply systems, 
P1 and P2, and supports dual power 
supply  redundancy. The power supply 
has the function of non-polarity 
connection, and the device can still work 
normally after the reverse connection. 

Voltage range: 9~60VDC. 

Relay Connection

 

This device provides 6-pin 5.08mm pitch 
terminal blocks, relay occupies the right 2 
pins. The relay is a group of   normally 
closed  contacts, which is closed  in 
normal no-alarm state and open  when 

any alarm information occurs. For example, they are open 
when powered off, and send out alarm. The switch supports 1 
relay alarm information output that can output DC power 
supply alarm information or network abnormality alarm. It can 
be connected to alarm light or alarm buzzer or other switching 
value collecting devices, which can timely inform operators 
when the alarm occurs.

 

DIP Switch Settings

 

The device provides 4-pin DIP switch for function 
setting, in which “ON” is the enabled end. The 
definitions of DIP switch are as follows: 

DIP 

Definition 

Operation 

Restore Factory 
Settings 

First dial the DIP switch to 
"ON", then put back the DIP 
switch. 

2- 4 

 

 

Console Port Connection

 

The device provides 1 program debugging port 
based on RS-232 serial port which can conduct 
device CLI command management after 

connecting to PC. The interface adopts RJ45 port, the RJ45 
pin definition as follows: 

Pin No. 

Definition 

TXD 

RXD 

GND 

Checking LED Indicator

 

The device provides LED indicators to monitor its operating 
status, which has simplified the overall troubleshooting 
process. The function of each LED is described in the table 
below: 

LED 

Indicate  Description 

RUN 

Blinking  The device is running normally 

OFF 

Device is not started or device is 
abnormal 

ALM 

ON 

Power, port or other configuration 
event has alarms 

OFF 

Power, port and other configuration 
event has no alarm. 

P1-P2 

ON 

Power supply is running normally 

OFF 

Device is not powered on or device 
is abnormal 

GE 1-10 

ON 

Ethernet port has established a 
valid network connection 

Blinking 

Ethernet port  is in an active 
network status 

OFF 

Ethernet port has not established a 
valid network connection. 

Logging in to WEB Interface

 

This device supports WEB management and configuration. 
Computer can access the device via Ethernet interface. The 
way of logging in to device’s configuration interface via IE 
browser is shown as below: 

 

Configure the IP addresses of computer and the 
device to the same network segment, and the 
network between them can be mutually accessed 

 

Enter device’s IP address in the address bar of the 
computer browser. 

 

 

Enter device’s username and password in the login 
window as shown below. 