Frame MIN Size is 64 Bytes.
Synthetic
Synthetic frame LM is enable. This is SLM/SLR/1SL PDU based LM.
Ended
Single: Single ended Loss Measurement implemented on LMM/LMR or SLM/SLR.
Dual: Dual ended Loss Measurement implemented on SW based CCM or 1SL.
FLR Interval
This is the interval in number of measurement intervals where the interval Frame Loss
Ratio is calculated.
Meas Interval
This is the 'synthetic' LM measurement interval in milliseconds. This must be a whole
number of the LM PDU transmission interval (inverse 'Rate'). This is the interval in time
where the loss and FLR is calculated based on the counted number of SL OAM PDUs.
It is in this interval that the calculated FLR is checked against availability, high loss and
degraded FLR threshold.
For example: 'Rate' = 100f/sec => 'Meas Interval' = N*10 milliseconds.
For example: 'Rate' = 10f/sec => 'Meas Interval' = N*100 milliseconds.
In case of service frame based LM this attribute is not used and the measurement
interval is always the LM PDU transmission interval.
Loss Threshold
Far end loss threshold count is incremented if a loss measurement is above this
threshold.
SLM Test ID
The Test ID value to use in SLM PDUs (see G.8013, section 9.22.1). The default value
is 0.
Loss Measurement State
Peer MEP
The Peer MEP ID that the following state relates to.
Tx
The accumulated transmitted LM PDUs - since last 'clear'.
Received
The accumulated received LM PDUs - since last 'clear'.