background image

PS5010G-2GS-8PoE User Manual

21

parameter description

parameter

description

Source port

To monitor the port in and out of flow

Destination port

Set destination port, All packets on the source port are copied and
forwarded to the destination port

Mirror group

Range :1-4

instructions

The port of the aggregate port can not be used as a destination port and the source port,
destination port and source port can not be the same.

Configuration example

Such as: set a mirror group for port 3 regulatory port 4, 5, 6 on and out flow conditions.

4.2.4 Port rate-limit

In the navigation bar to select

“PORT>port rate-limit ”

,

Summary of Contents for PS5010G-2GS-8PoE

Page 1: ...PS5010G 2GS 8PoE User Manual PS5010G 2GS 8PoE Managed Full Gigabit Industrial Ethernet PoE Switch User Manual Version 1 0 2017 8 29 ...

Page 2: ... 3 Switch connection to the PD 9 Chapter 3 How to Login the Switch 11 3 1 Switch to End Node 11 3 2 How to Login the Switch 11 Chapter 4 Switch Configuration 14 4 1 Quickly setting 14 4 2 PORT 17 4 2 1 Basic config 17 4 2 2 Port aggregation 19 4 2 3 Port mirroring 20 4 2 4 Port rate limit 21 4 2 5 Storm control 23 4 2 6 Port isolation 24 4 3 VLAN 26 4 3 1 VLAN config 26 4 3 2 Trunk port setting 27...

Page 3: ...ue mapping 53 4 8 3 2 Differential service class mapping 54 4 8 3 3 Port to service class mapping 55 4 9 Address table 56 4 9 1 Mac add and delete 57 4 9 2 Mac study and laging 58 4 9 3 Mac address filtering 60 4 10 SNMP 60 4 10 1 Snmp config 61 4 10 1 1 Snmp config 61 4 10 1 2 Community config 61 4 10 1 3 View config 62 4 10 1 4 Group config 63 4 10 1 5 User config 64 4 10 1 6 Trap 66 4 10 2 Rmon...

Page 4: ...stem log 77 4 11 2 System upgrade 79 4 11 3 Config management 80 4 11 3 1 Current configuration 80 4 11 3 2 Configuration backup 82 4 10 3 3 Restore factory configuration 83 4 11 4 Config save 84 4 11 5 Administrator privileges 84 4 11 6 Info collect 85 Appendix Technical Specifications 87 ...

Page 5: ...sy to maintenance and management meet the networking and access requirements of small and medium sized enterprises intelligent village hotel office network and campus network The is 8 ports have POE power supply function support IEEE802 3at standard 802 3af downward compatibility power supply equipment for Ethernet can automatically detect identification standard of electrical equipment and throug...

Page 6: ...erminal for monitoring and configuring the Switch SFP ports SFP1 SFP2 Designed to install the SFP module and connect to the device with a bandwidth of 1000Mbps Each has a corresponding 1000Mbps LED RESET button RESET Keep the device powered on and push a paper clip into the hole Press down the button for 2 seconds to reboot the Switch Press down the button for 5 seconds to restore the Switch to it...

Page 7: ... may be in short or the power current may be overloaded LINK ACT 9S 10S Green On A device is connected to the port Off A device is disconnected to the port Flashing Sending or receiving data 1 3 2 Rear Panel The rear panel of the Switch contains AC power connector and one marker shown as below Figure 3 Rear Panel AC Power Connector Power is supplied through an external AC power adapter It supports...

Page 8: ...PS5010G 2GS 8PoE User Manual 7 One PoE Web Smart Ethernet Switch Four rubber feet two mounting ears and eights screws One AC power cord One User Manual ...

Page 9: ...proper heat dissipation from and adequate ventilation around the Switch Make sure the cabinet to enough back up the weight of the Switch and its accessories 2 1 1 Desktop Installation Sometimes users are not equipped with the 11 inch standard cabinet So when installing the Switch on a desktop please attach these cushioning rubber feet provided on the bottom at each corner of the Switch in case of ...

Page 10: ...onnect the AC power connector in the back panel of the Switch to external receptacle with the included power cord and check the power indicator is ON or not When it is ON it indicates the power connection is OK 2 2 Connect Computer NIC to the Switch Please insert the NIC into the computer after installing network card driver please connect one end of the twisted pair to RJ 45 jack of your computer...

Page 11: ...oE User Manual 10 30W each port it can make PD devices such as internet phone network camera wireless access point work You only need to connect the Switch PoE port directly connected to the PD port by network cable ...

Page 12: ...witch provides Web based management login you can configure your computer s IP address manually to log on to the Switch The default settings of the Switch are shown below Parameter Default Value Default IP address 192 168 2 1 Default user name admin Default password admin You can log on to the configuration window of the Switch through following steps 1 Connect the Switch with the computer NIC int...

Page 13: ...al 12 Figure 7 Login Windows 5 Switching language to english Enter the Username and Password The factory default Username is admin and Password is admin and then click LOGIN to log in to the Switch configuration window as below ...

Page 14: ...PS5010G 2GS 8PoE User Manual 13 ...

Page 15: ...can see the information for switch system such as memory software version The middle shows the switch s current link status Green squares indicate the port link is up while black squares indicate the port link is down Below the switch panel you can find a common toolbar to provide useful functions for users The rest of the screen area displays the configuration settings 4 1 Quickly setting In the ...

Page 16: ...r receive a message on the interface is considered belongs to the VLAN Obviously the interface of the default VLAN ID PVID in the IEEE 802 1 Q VLAN ID is the Native VLAN At the same time send belong to Native VLAN frame on the Trunk must adopt UNTAG way Allowed VLAN list a Trunk can transport the equipment support by default all the VLAN traffic 1 4094 But also can by setting the permission VLAN T...

Page 17: ...010G 2GS 8PoE User Manual 16 2 click next step button into other settings such as manage ip address set as 192 168 2 11 device name set as switch 123 default gateway with the dns server set as 172 16 1 241 ...

Page 18: ... bar to select PORT You may conduct basic config port aggregation port mirroring port limit and port isolation 4 2 1 Basic config In the navigation bar to select PORT basic config For panel port to port described port speed port status working mode flow control cross line order configuration the following picture ...

Page 19: ...000 M working mode Can choose the following kinds Self negotiated 10 M 100 M 1000 M port described The port is described Cross line sequence Whether open intersection line sequence instructions Open flow control should be negotiated will close negotiated close is to set port speed rate and working mode Set the port rate more than actual rate of port the port will be up Configuration example Such a...

Page 20: ...ing picture parameter description parameter description Aggregation port 8 GE switch can be set up eight link trunk group group_1 to group_8 Member port For each of the members of the group and add your own port and with members of other groups instructions Open the port of the ARP check function the port of the important device ARP the port of the VLAN MAC function and the monitor port in the por...

Page 21: ...n port 1 to build switch links 4 2 3 Port mirroring In the navigation bar to select PORT port mirroring Open port mirror feature All packets on the source port are copied and forwarded to the destination port Destination port is usually connected to a packet analyzer to analyze the source port Multiple ports can be mirrored to a destination port the following picture ...

Page 22: ...pied and forwarded to the destination port Mirror group Range 1 4 instructions The port of the aggregate port can not be used as a destination port and the source port destination port and source port can not be the same Configuration example Such as set a mirror group for port 3 regulatory port 4 5 6 on and out flow conditions 4 2 4 Port rate limit In the navigation bar to select PORT port rate l...

Page 23: ...meter description Input speed limit Set port input speed Output speed limit Set port output speed instructions 1 Mbit s 1000 Kbit s 1000 8 KB s 125 KB s That is the theoretical rate of 1M bandwidth is125KB s Configuration example Such as the port 5 input rate is set to 6400 KB s the output rate is set to 3200 KB s ...

Page 24: ...PS5010G 2GS 8PoE User Manual 23 4 2 5 Storm control In the navigation bar to select PORT Storm control To port storm control config the following picture parameter description ...

Page 25: ...icast suppression value Storm suppression value of the unicast packets instructions 1 Mbit s 1000 Kbit s 1000 8 KB s 125 KB s That is the theoretical rate of 1M bandwidth is125KB s Configuration example Such as should be forwarded to the port 1 8 of all kinds of packet forwarding rate is 5000 KB s 4 2 6 Port isolation In the navigation bar to select PORT port isolation ports are isolated the follo...

Page 26: ...tructions Open port isolation function All packets on the source port are not forwarded from the isolated port the selected ports are isolated Ports that have been added to the aggregate port aren t also capable of being a destination port and source port destination port and source port cannot be the same Configuration example Such as the port 3 4 5 and 6 ports isolated ...

Page 27: ...gs the following picture 4 3 1 VLAN config In the navigation bar to select VLAN config Vlans can be created and set the port to the VLAN port default state for the access mode the following picture parameter description parameter description VLAN ID VLAN number 8 GE default VLAN 1 VLAN name VLAN mark VLAN IP address Manage switch ip address ...

Page 28: ...er of the VLAN Configuration example Such as connect switches pc1 pc2 couldn t ping each other will be one of the PC connection port belongs to a VLAN 2 4 3 2 Trunk port setting In the navigation bar to select VLAN config trunk port setting can set port to Trunk port the following picture parameter description parameter description Native VLAN Only set one ...

Page 29: ...VLAN At the same time send belong to Native VLAN frame on the Trunk must adopt UNTAG way Allowed VLAN list a Trunk can transport the equipment support by default all the VLAN traffic 1 4094 But also can by setting the permission VLAN Trunk at the mouth of the list to limit the flow of some VLAN can t through the Trunk Configuration example Such as PVID VLAN2 PC1 192 168 2 122 port 8 access VLAN2 P...

Page 30: ...r the Hybrid port allows the VLAN data into if can be forwarded or discarded untag on port configuration is not considered untag configuration only work when to send it a message Hybrid port to send packet 1 determine the VLAN in this port attributes disp interface can see the port to which VLAN untag which VLAN tag 2 if it is untag stripping VLAN information send again if the tag is sent directly...

Page 31: ...LAN is untagged 10 then switches at this time to remove packet VLAN10 tag in the form of ordinary package sent to pc2 pc1 p2 is VLAN10 walking at this time Again to analyze pc2 gave pc1 package process data from the pc2 by inter0 2 pvid VLAN20 encapsulation VLAN20 labeled into switch switch found system e0 1 allows VLAN by 20 data so the data is forwarded to the system e0 1 because the system e0 1...

Page 32: ...tercepting counterfeit DHCP server and address depletion attack packets ban kangaroo DHCP server the following picture instructions DHCP trusted port configuration select the port as a trusted port Prohibit DHCP for address select the port and save you can disable this feature for the port Open DHCP attack prevention function need to set the DHCP protective vlan simultaneously other functions to t...

Page 33: ...0G 2GS 8PoE User Manual 32 Set the connection router 8 ports for trust then 6 port is set to the prohibit 3 Verify source mac F0 DE F1 12 98 D2 set server ip address to 192 168 2 1 4 Set option82 information ...

Page 34: ...attack packets illegal TCP packets to ensure that the device or server to provide normal service to legitimate users the following picture instructions Open the anti DOS attack function intercept Land attack packets illegal TCP packets to ensure that the device or server to provide normal service to legitimate users Configuration example Such as Open the anti DOS attack function ...

Page 35: ...the packet filter control prevent illegal message through the port thereby limiting the illegal use of network resources improve the safety of the port the following picture instructions Add the port that is currently being used as a IP source protection enable port the port will not be able to use Configuration example Such as to open source IP protection enabled port first then to binding ...

Page 36: ...dress of the mapping relationship and then realize the function of a key binding the following picture instructions A bond must be bound before the binding to enable the switch to open And if you want to access shall be binding and switch the IP address of the same network segment Configuration example Such as the binding to make first can open must be a key bindings port 7 ...

Page 37: ...l 36 Can check the delete option 4 4 2 Channel detection 4 4 2 1 Ping In the navigation bar to select fault safety channel detection ping Use ping function to test internet connect and host whether to arrive The following picture ...

Page 38: ...on example Such as PING connect the IP address of the PC 4 4 2 2 Tracert In the navigation bar to select fault safety channel detection tracert Tracert detection can detect to the destination through the following picture parameter description parameter description destination IP address Fill in the IP address of the need to detect Timeout period Range of 1 to 10 instruction the function is used t...

Page 39: ...C 4 4 2 3 Cable test In the navigation bar to select fault safety channel detection cable test Can detect connection device status the following picture Configuration example 4 4 3 ACL In the navigation bar to select fault safety ACL Can be applied to port ACL rules and Settings to take effect in time ...

Page 40: ...meet will not continue to find 2 implied refused if don t match so must match the final implied refused entry cisco default 3 any only under the condition of the minimum permissions to the user can satisfy their demand 4 don t forget to apply the ACL to the port Configuration example such as test time is every Monday to Friday 9 to 18 points set port 1 6 cannot access the network steps building AC...

Page 41: ...PS5010G 2GS 8PoE User Manual 40 4 5 POE In the navigation bar to select POE you can set to the POE Config POE Port Config and POE Delay Config configuration ...

Page 42: ... Configure alert notification status instruction The actual application needs to control the system in the power change and the power of the port on whether to send a trap notification Receiving Trap notification required to open the Snmp and set the trap target host Configuration example Such as For example the alarm notification is set to 126W the reserved power is 9 4 5 1 2 Temperature distribu...

Page 43: ...uration example Such as The 1 chip alarm threshold is set to 90 4 5 2 POE Port Config In the navigation bar to select POE POE Port Config you can be set to port POE As follows parameter description parameter description Power MAX Select the maximum power of the configured port POE mode Enable state of the selected configuration Priority Configure port priority when the load exceeds the maximum pow...

Page 44: ...e opened the maximum power of 23 W the detection mode is AF the priority is high 4 5 3 POE Delay Config In the navigation bar to select POE POE Delay Config you can be set to port POE As follows parameter description parameter description Port Restart Time Set port restart limit time Port Delay Time Set the delay time for port POE power supply instruction Receiving Trap notification required to op...

Page 45: ... delay time is 20 seconds 4 6 STP In the navigation bar to select STP you can set to the MSTP region and STP bridge configuration 4 6 1 MSTP region In the navigation bar to select STP MSTP region Can modify the domain and domain name add instance is mapped to a VLAN the following picture parameter description ...

Page 46: ...he VLAN configuration instance instruction An instance can only be mapped to a VLAN instance and VLAN is a one to one relationship Configuration example Such as change the region to DEADBEEF0102 region name is 123 instance 4 is mapped to a VLAN 2 in the first need to create a VLAN 2 4 6 2 STP bridge In the navigation bar to select STP STP bridge Can be related to bridge port configuration the foll...

Page 47: ...essage in the time will initiate topology changes Forward delay The state of the port switch time Port priority Set port instance priority defaults to 128 you must enter multiple of 16 the range of 0 240 Path cost Configure port costs Port fast Select configuration state Auto ege Select configuration state Point to point Select configuration state Bpdu guard Select configuration state Bpdu filter ...

Page 48: ...figuration has to create an instance of the priority configuration time parameters set the pattern to MSTP 2 Set MSTP has launched port configuration select the created instance set priority port configuration is not online on line configuration will only take effect can click on the view the current configuration button to view the configured completed ...

Page 49: ...IP address and its status the following picture parameter description parameter description IP address DHCP server address status Invalid and vaild instruction If open the function of relay agent then receives the broadcast DHCP message to be delivered in the form of unicast to configure on the server The DHCP server to IP and switches in the same network segment will only take effect Configuratio...

Page 50: ... range is 1 4094 Circuit control Circuit ID to populate the user custom content scope of string length is 3 63 Proxy remote Configuration ASCII remote id string value the length of the range of 1 63 IP address Decimal IP address instruction Switches relay information to the DHCP server will take option82 VLAN ID must be configured to DHCP message taken VLAN can bring option82 information Configura...

Page 51: ...oS In the navigation bar to select QoS you can set to the Remark queue config and mapping the queue 4 8 1 Remark In the navigation bar to select QoS Remark According to the rules for port traffic bag tag or queue map the following picture ...

Page 52: ...ing rules such as choice goal Mac just check the data destination Mac address is in accordance with the rules value Set the value of matching such as choice goal Mac for HH HH HH HH HH HH Choose port to config The application of heavy tag on which interface apply Click on the application of heavy marking rules to take effect instruction According to the different matching rules to map different pa...

Page 53: ...he navigation bar to select QoS queue config Can be set up queue scheduling policy the following picture parameter description parameter description Scheduling strategy Can choose four kinds of modes RR round robin scheduling SP absolute priority scheduling ...

Page 54: ...egy for WRR weight value respectively 10 11 12 12 14 15 16 17 4 8 3 Mapping the queue 4 8 3 1 Service class queue mapping In the navigation bar to select QoS mapping the queue Service category can be mapped to the corresponding queue the following picture parameter description parameter description Server ID COS the VLAN priority fields 0 to 7 Queue ID Set each cosine value mapping queue number 0 ...

Page 55: ...ce can be mapped to the corresponding service categories the following picture parameter description parameter description Server list DSCP field has seven 0 63 is divided into four tables Queue ID Map the DSCP to COS fields 0 to 7 based on the cosine is mapped to a queue instruction Cos priority is greater than the DSCP DSCP priority is greater than the port Configuration example ...

Page 56: ...queue port to service class mapping Port can be mapped to the corresponding service categories the following picture parameter description parameter description Port Select the port number 1 10 Service ID Mapped to the service ID and then according to the service ID into the queue instruction Cos priority is greater than the DSCP DSCP priority is greater than the port ...

Page 57: ... Manual 56 Configuration example Such as port 4 5 6 respectively cos4 cos5 cos6 4 9 Address table In the navigation bar to select Address table you can set to MAC add and delete MACstudy and aging and MAC address filtering ...

Page 58: ...description Clear Mac Can choose to clear the multicast Mac address clear dynamic unicast Mac address clear static unicast Mac address clear the specified Mac address Mac address table VLAN Fill in the need to add or delete VLAN id not create vlans to create can only take effect instruction According to different conditions to clear Mac address view add learn the Mac address Mac address filtering ...

Page 59: ...al 58 2 clear port 6 static Mac addresses 4 9 2 Mac study and laging In the navigation bar to select address table Mac study and laging Can be set up port Mac address study limit and Mac address aging time the following picture ...

Page 60: ...ddress Range 0 8191 default 8191 Mac address study limit Default 300 Configuration example Such as 1 setting port 2 3 4 5 address study limit for 2000 2 will be dropped or learn the Mac address of the port equipment after 2 minutes disappear automatically from the Mac address table ...

Page 61: ...ndition does not need the Mac address the following picture parameter description parameter description Mac address Can not add multicast Mac address VLAN VLAN number Configuration example Such as the Mac address for 00 20 15 09 12 12 added to the filter in the table 4 10 SNMP In the navigation bar to select SNMP you can set to the Snmp config and Rmon config ...

Page 62: ...mp function enable the following picture instruction The SNMP function must be turned on in the configuration RMON otherwise it will be configured to fail Configuration example Such as open Snmp 4 10 1 2 Community config In the navigation bar to select Snmp Snmp config community config Can specify group access the following picture ...

Page 63: ...s can only be read cannot be modified Read only can write specify the NMS Snmp host of MIB variables can only read can also be modified instruction The upper limit of the number of groups is 8 Configuration example Such as add a read write group called public 4 10 1 3 View config In the navigation bar to select Snmp Snmp config view config Set the view the rules to allow or disable access to some ...

Page 64: ...B subtree OID View the associated MIB object is a number of MIB subtree mask MIB OID mask instruction Each view is best to configure a view rule otherwise it will affect the SNMP function Configuration example such as establish a view 123 MIB subtree oid 1 3 6 1 contain among them 4 10 1 4 Group config In the navigation bar to select Snmp Snmp config group config setting Snmp group the following p...

Page 65: ...not need to be kept secret Both authentication and encryption this group of users need to verify the news of transmission and transmission of data need to be kept secret Read view read and write view study view The associated view name instruction Before the cap on the number set of configuration of 8 the new group needs a new view to create a group Configuration example Such as firstly new view 1...

Page 66: ...sion and transmission of data need to be kept secret Authentication mode Specified use MD5 authentication protocol or SHA authentication protocol Authentication password Range 8 10 encrypt mode Specified using AES encryption protocol or DES encryption protocol Group name A user group name encrypt password Range 8 60 instruction Cap on the number configuration of 8 users need a new view and group t...

Page 67: ...curity mode Specified using AES encryption protocol or DES encryption protocol Group name User group name instruction The Trap cap on the number configuration of 8 you can configure a number of different Snmp Trap host used to receive messages Trigger the trap message time port Linkup LinkDown equipment of cold start restart when power supply drop warm start a warm restart and Rmon set port port s...

Page 68: ...stics the following picture parameter description parameter description index The index number the value range of statistical information table is 1 65535 Interface mane To monitor the source port ower Set the table creator range 1 30 characters of a string instruction At the time of configuration Rmon Snmp functions must be open otherwise the prompt dialog box will appear ...

Page 69: ...e information the following picture parameter description parameter description index Historical control table item index number value range is 1 65535 Interface name To record the Ethernet interface Maximum number of samples Set the history control table item of the corresponding table capacity namely the Max for number of records the history table value range is 1 65535 Sample period Set up the ...

Page 70: ... Rmon config event group The way in which define events trigger and record them the following picture parameter description parameter description index The index number the value range of the event table is 1 65535 description The Trap events when the event is triggered the system will send the Trap message Log events when the event is triggered the system will log owner Set the table creator owne...

Page 71: ...ts 4 Octets 5 Pkts 6 BroadcastPkts 7 MulticastPkts 8 CRCAlignErrors 9 UndersizePkts 10 OversizePkts 11 Fragments 12 Jabbers 12 Collisions 14 Pkts64Octets 15 Pkts65to127Octets 16 Pkts128to255Octets 17 Pkts256to511Octets 18 Pkts512to1023Octets 19 Pkts1024to1518Octets statistical index Set up the corresponding statistics statistical index number decided to statistics to monitor the port number Sampli...

Page 72: ... reached for each event owner Set the table creator ownername for 1 30 characters of a string instruction At the time of configuration Rmon Snmp functions must be open otherwise the prompt dialog box will appear This configuration need to configure statistics groups and events Configuration example Such as new statistics group of 77 and the event group 345 set up more than 12 and below the lower l...

Page 73: ...ollowing picture parameter description parameter description Device name switch name Manage VLAN Switches use VLAN management Manage ip Switch IP address management timeout Don t use more than login timeout after login to log in again Configuration example Such as 1 set up the VLAN 2 is management VLAN should first created vlan 2 the VLAN Settings and set a free port in the VLAN 2 ...

Page 74: ...PS5010G 2GS 8PoE User Manual 73 2 insert the PC interface 9 or 10 ports set up the management IP for 192 168 2 12 device name is yoyo timeout for 20 minutes Jumboframe for 5000 ...

Page 75: ... 8PoE User Manual 74 3 use 192 168 1 12 logging in sets the system time 4 11 1 2 System restart In the navigation bar to select SYSTEM system config system restart equipment can be restarted the following picture ...

Page 76: ...s may take 1 minute Please wait patiently The page will be refreshed automatically after device restart Configuration example Such as click restart button 4 11 1 3 Password change In the navigation bar to select SYSTEM system config password change The password change to equipment the following picture ...

Page 77: ...the password reset can be reset in the console switch config password admin New Password 3456 Confirm Password 3456 Configuration example Such as amend the password to 1234 4 11 1 4 SSH login In the navigation bar to select SYSTEM system config ssh login SSH open the following picture instruction Configure the user to be able to switch through the SSH login device Configuration example Such as SSH...

Page 78: ...e following picture instruction Configure the user to be able to switch through the Telnet login device Configuration example Such as Telnet open PC Telnet functiono open you can log in 4 11 1 6 System log In the navigation bar to select SYSTEM password change system log to view the log and set up the log server the following picture ...

Page 79: ...g level 0 7 key Enter the required query of characters instruction Open log switch set up the syslog server system log will automatically be pushed to the server Configuration example Such as 1 the error log information in 192 168 2 1 pushed to the server 2 input the Mac keywords click query button click on the clear log button can clear the log ...

Page 80: ...ile to upgrade the following picture instruction 1 please confirm that the upgraded version of the same model and the same model 2 in the upgrade process you may encounter flash to make the page is temporarily unable to respond to the page this time can not power off or restart the device until prompted to upgrade successfully ...

Page 81: ...le the following picture instruction Import process can not be closed or refresh the page or import will fail After the introduction of configuration to enable the new configuration please in this page Restart device Otherwise configuration does not take effect Configuration example Such as 1 in the configuration first save the page click save configuration to save the current configuration then e...

Page 82: ...PS5010G 2GS 8PoE User Manual 81 2 import configuration 3 backup ...

Page 83: ...he navigation bar to select SYSTEM config management configuration backup you can configure backup file the following picture instruction Operating this page should be in the current configuration page first the backup file Configuration example Such as restore backup ...

Page 84: ...tion and restore factory configuration the following picture instruction Restore the factory configuration will delete all the current configuration If you have any useful configuration the current system can lead the factory configuration again after the current configuration Configuration example Such as restore configuration can be the guide before they leave the current configuration ...

Page 85: ...the following picture instruction Save settings will delete all default configurations If there are useful configurations clickbackup Configurationsbefore save the settings Configuration example Such as click save settings button 4 11 5 Administrator privileges In the navigation bar to select SYSTEM administrator privileges Configurable ...

Page 86: ...tors The user can log in the Web management system of equipment for routine maintenance In addition to the admin and user can add up to five users Ordinary users can only access information system home page Configuration example Such as 4 11 6 Info collect In the navigation bar to select SYSTEM info collect you can collect to the system debug information the following picture ...

Page 87: ...PS5010G 2GS 8PoE User Manual 86 instruction collect useful infomation it may take a few moment Configuration example Such as click on collect button ...

Page 88: ...n ports 2 x 1000Mbps SFP ports 1 x Console port Transfer Method Store and Forward Switching Capacity 20Gbps MAC Address Table 8K Packet Forwarding Rate 14 88Mpps Packet Buffer 4 1Mbit Jumbo Frame 9216Bytes PoE Ports RJ45 8 PoE ports compliant with 802 3at af Power Pin Assignment 1 2 3 6 PoE Budget 140W MAC Address Learning Automatically learning automatically update 8K Table Dimensions L W H 280 1...

Page 89: ...trust port Static routing capacity Ping and Traceroute The security policy ACE capacity ACL QoS DAI VLAN Port based VLAN 802 1Q VLAN Safety features Radius Tacacs Preventing DOS attacks dot1x The gateway ARP deception Application protocol DHCP Relay DHCP snooping DHCP Client FTP TFTP Management HTTP WEB Telnet SSH Console Other function LLDP IGMP Snooping SNMPV1 V2c V3 RMON 1 2 3 9 POE Management ...

Reviews: