PS5026G-2GS-24PoE User Manual
64
【
Instruction
】
At the time of configuration RMON SNMP functions must be open, otherwise the prompt
dialog box will appear.
【
Configuration Example
】
Such as: Monitor Ethernet port 4 historical information.
4.10.2.3 Alarm Group
In the navigation bar to select
"SNMP>RMON Config>Alarm Group"
, define alarm group
as shown.
【
Parameter Description
】
Parameter
Description
Index
The alarm list items index number, value range is 1 ~
65535
Static table
Statistical type values :3:DropEvents; 4:Octets; 5:Pkts;
6:BroadcastPkts;
7:MulticastPkts;
8:CRCAlignErrors;
9:UndersizePkts;
10:OversizePkts;
11:Fragments;
12:Jabbers;
12:Collisions;
14:Pkts64Octets;
15:Pkts65to127Octets;
16:Pkts128to255Octets;
17:Pkts256to511Octets;
18:Pkts512to1023Octets;
19:Pkts1024to1518Octets
Statistical index
Set up the corresponding statistics statistical index number,
decided to statistics to monitor the port number
Sampling interval
Sampling time interval, the scope for 5 ~ 65535, the unit for
seconds
The sampling type
Sample types for the absolute value of sampling, the