signal Negative
3
RD+
100M Ethernet received
signal positive
4
RD-
100M Ethernet received
signal negative
M12 Gigabit Copper Port
This
device
provides
4
10/100/1000Base-T(X)
interfaces.
The
interface type is M12 A-Coded 8-Pin slot
(female) and its pin definitions are as follow:
No.
Definition
Description
1
D0+ (DA+)
The first group of bi-directional
data of Gigabit Ethernet
positive
2
D0- (DA-)
The first group of bi-directional
data of Gigabit Ethernet
negative
3
D1+ (DB+)
The second group of
bi-directional data of Gigabit
Ethernet positive
4
D1- (DB-)
The second group of
bi-directional data of Gigabit
Ethernet negative
5
D3+ (DD+)
The fourth group of
bi-directional data of Gigabit
Ethernet positive
6
D3- (DD-)
The fourth group of
bi-directional data of Gigabit
Ethernet negative
7
D2- (DC-)
The third group of
bi-directional data of Gigabit
Ethernet negative
8
D2+ (DC+)
The third group of
bi-directional data of Gigabit
Ethernet positive
【
Checking LED Indicator
】
This device provides LED indicators for monitoring the work
status of the device, which has simplified the troubleshooting
process comprehensively. The function of each LED is
described in the table as below:
LED
Status
Description
PWR
ON
PWR is connected and
running normally
OFF
PWR is disconnected and
running abnormally.
ALARM
ON
Power supply, port link alarm
OFF
Power supply, port link
without alarm
RUN
ON
The device is powered on or
the device is abnormal.
OFF
The device is powered off or
the device is abnormal.
Blinking
Blink 1 time/s, system is
running well.
Link/Act
(1-8/G1-G4)
ON
Ethernet port connection is
active.
Blinking Data transmitted
OFF
Ethernet port connection is
inactive.
【
Logging in to WEB Interface
】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device
’s configuration interface via IE
browser is shown as below:
Configure the IP addresses of computer and the
Step 1
device to the same network segment, and the
network between them can be mutually accessed.
Enter device
’s IP address in the address bar of the
Step 2
computer browser.
Enter device
’s username and password in the login
Step 3
window as shown below.
Click
“OK” button to login to the WEB interface of
Step 4
the device.
Note:
The default IP address of the device is “192.168.1.254”.
The default username and password of the device is
“admin123”.
If the username or password is lost, user can restore it to
factory settings via device DIP switch or management
software; all modified configurations will be cleared
after restoring to factory settings, so please backup
configuration file in advance.
Please refer to user manual for specific configuration
method of logging in to WEB interface and other
configurations about network management function.
【
Specification
】
Panel
100M M12
10/100Base-T(X), M12
(Female), 4-Pin D-Coded,
automatic flow control, full/half
duplex mode, MDI/MDI-X
automatic detection