background image

signal Negative 

RD+ 

100M Ethernet received 

signal positive 

RD- 

100M Ethernet received 

signal negative 

 

M12 Gigabit Copper Port 

This 

device 

provides 

10/100/1000Base-T(X) 

interfaces. 

The 

interface  type  is  M12  A-Coded  8-Pin  slot 

(female) and its pin definitions are as follow: 

No. 

Definition 

Description 

D0+ (DA+) 

The first group of bi-directional 

data of Gigabit Ethernet 

positive 

D0- (DA-) 

The first group of bi-directional 

data of Gigabit Ethernet 

negative 

D1+ (DB+) 

The second group of 

bi-directional data of Gigabit 

Ethernet positive 

D1- (DB-) 

The second group of 

bi-directional data of Gigabit 

Ethernet negative 

D3+ (DD+) 

The fourth group of 

bi-directional data of Gigabit 

Ethernet positive 

D3- (DD-) 

The fourth group of 

bi-directional data of Gigabit 

Ethernet negative 

D2- (DC-) 

The third group of 

bi-directional data of Gigabit 

Ethernet negative 

D2+ (DC+) 

The third group of 

bi-directional data of Gigabit 

Ethernet positive 

Checking LED Indicator

 

This device provides LED indicators for monitoring the work 

status of the device, which has simplified the troubleshooting 

process comprehensively. The function of each LED is 

described in the table as below:   

LED 

Status 

Description 

PWR 

ON 

PWR is connected and 

running normally 

OFF 

PWR is disconnected and 

running abnormally. 

ALARM 

ON 

Power supply, port link alarm 

OFF 

Power supply, port link 

without alarm 

RUN 

ON 

The  device  is  powered  on  or 

the device is abnormal. 

OFF 

The  device  is  powered  off  or 

the device is abnormal. 

Blinking 

Blink  1  time/s,  system  is 

running well. 

Link/Act 

(1-8/G1-G4) 

ON 

Ethernet  port  connection  is 

active. 

Blinking  Data transmitted 

OFF 

Ethernet  port  connection  is 

inactive. 

Logging in to WEB Interface

 

This  device  supports  WEB  management  and  configuration. 

Computer  can  access  the  device  via  Ethernet  interface.  The 

way  of  logging  in  to  device

’s  configuration  interface  via  IE 

browser is shown as below: 

 

Configure  the  IP  addresses  of  computer  and  the 

Step 1

device  to  the  same  network  segment,  and  the 

network between them can be mutually accessed. 

 

Enter device

’s IP address in the address bar of the 

Step 2

computer browser. 

 

 

Enter device

’s username and password in the login 

Step 3

window as shown below. 

 

 

Click 

“OK” button to login to the WEB interface of 

Step 4

the device. 

Note: 

 

The default IP address of the device is “192.168.1.254”. 

 

The  default  username  and  password  of  the  device  is 
“admin123”. 

 

If the username or password is lost, user can restore it to 

factory  settings  via  device  DIP  switch  or  management 

software;  all  modified  configurations  will  be  cleared 

after  restoring  to  factory  settings,  so  please  backup 

configuration file in advance. 

 

Please  refer  to  user  manual  for  specific  configuration 

method  of  logging  in  to  WEB  interface  and  other 

configurations about network management function. 

Specification

 

Panel

 

 

100M M12 

10/100Base-T(X), M12 

(Female), 4-Pin D-Coded, 

automatic flow control, full/half 

duplex mode, MDI/MDI-X 

automatic detection   

Summary of Contents for TNS5800D Series

Page 1: ...ed for rail transit industry The module is TNS5800D 4GT 8T 4 Gigabit copper ports 8 100M copper ports Panel Design Front view Bottom view Top view Left view Right view 1 Hanger 2 Relay alarm output terminal block 3 Console port 4 Indicator of power supply input status PWR 5 Relay alarm indicator ALARM 6 Indicator of device running status RUN 7 Grounding screw 8 Power input terminal block 9 10 100 ...

Page 2: ...emale Power supply range 110VDC 70 160VDC The pin definitions of M12 Male are as follows No 1 2 3 4 Definition FG V V NC Description Ground Power input negative Power input positive reserved Relay Connection This device provides 1 M12 D Coded 4 Pin slot female for relay output R1 and R2 is a pair of normally open contacts of device alarm relay They are open circuit in normal non alarm state closed...

Page 3: ...N ON The device is powered on or the device is abnormal OFF The device is powered off or the device is abnormal Blinking Blink 1 time s system is running well Link Act 1 8 G1 G4 ON Ethernet port connection is active Blinking Data transmitted OFF Ethernet port connection is inactive Logging in to WEB Interface This device supports WEB management and configuration Computer can access the device via ...

Page 4: ...output M12 D coded port Indicator Power indicator run indicator interface indicator alarm indicator Exchange attributes Backplane bandwidth 128G Packet buffer size 12Mbit MAC table size 16K Power supply Input power supply 110VDC 70 160VDC M12 A coded port Consumption No load 14 30W 110VDC Full load 14 85W 110VDC Working environment Working temperature 40 75 Storage temperature 40 75 Working humidi...

Reviews: