background image

Powered by

www.3sense.tech

Nov. 2018

This device is part of 3Sense product family

4. Normal Operating Mode and Alternative Device States

The product has 3 LEDs, 2 external push buttons and a micro-USB connector.

The LEDs are:

- Battery charge – This LED turns RED while the product is charging the battery. In addition,

it will turn GREEN while the device it transmitting to the Sigfox network.

- MCU – this LED will flash with a code that relates to battery level.

- GPS – this LED will flash slowly if the GPS is on and there is no location fix and will flash

shortly when the GPS has a location fix.

The 2 push buttons are:

- ON/OFF button – if pressed for more than 2 seconds it will change the product state from

ON to OFF and from OFF to ON. When the product is turned ON it will flash the MCU and

GPS LEDs once at the same time. When it is turned OFF, it will flash the MCU and GPS LEDs

twice at the same time. If pressed for less than 2 seconds and the device is ON, it will

report the battery level using the MCU LED.

- The SOS button – When the device is ON, if pressed it will generate an event (if enabled)

that can be sent to the Sigfox network.

4.1. Send Data

The configured publication time (Normal or Alarm Publication Time) for each sensor will naturally

limit the data transmissions executed by GPS-TS. However

, the device may be forced to send its

readings after briefly pressing its ON/OFF Button 1 time.

LED  Indicator  will  flash  green  only  to  show  that  the  device  is  configuring  its  Communications

Module.

Summary of Contents for GPS-TS

Page 1: ...GPS TS User Manual General Guidelines Nov 2018...

Page 2: ...cking the above you can get technical assistance by dialing 1 786 584 7439 Monday thru Friday 7 00 a m to 5 00 p m Eastern Standard Time You can also email your request to info 3sense tech Specialized...

Page 3: ...Main Unit 2 3 Mounting Indications 2 3 1 Main Unit 3 Electrical Installation Foreword 3 1 Power Requirements 4 Normal Operating Mode and Transmission Test Mode 4 1 Send Data 5 3Sense Remote Monitoring...

Page 4: ...at devices have to the 3Sense Monitoring System through its inbuilt communication module a platform accessible from any mobile computing device computer tablet smartphone abled for internet navigation...

Page 5: ...o it s ready to mount 2 1 Environmental Considerations IP66 No ingress of dust complete protection against contact dust tight No ingress of water when submerged up to a depth of 1 meter for 30 minutes...

Page 6: ...out holder 190g with magnetic holder 2 3 Mounting Indications 2 3 1 Main Unit Using magnetic holder it is only necessary to stick it to a metal surface Or to secure main unit enclosure to a surface 1...

Page 7: ...any malfunction on the process to be managed due to unexpected operating failures to which any electronic system is susceptible 3 1 Power Requirements Among other hardware and firmware precautions GPS...

Page 8: ...seconds it will change the product state from ON to OFF and from OFF to ON When the product is turned ON it will flash the MCU and GPS LEDs once at the same time When it is turned OFF it will flash th...

Page 9: ...among other things Remote monitoring and visualization of historical data records in graphs and data tables from up to 2 years Alarm management for variables out of range battery levels and main power...

Page 10: ...e any information desired if using an account with permission to do so however by default it offers panels for remote monitoring of the data published by each device linked to the platform and panels...

Page 11: ...s data from sensors and transmits them through a particular network to the platform Thus each Device visible to an account receives the data of the physical equipment acquired by the administrator of...

Page 12: ...ation that corresponds to said Device in multiple panels and Variables Reviewing the Variables of a certain Device allows checking the update status and presence of each Variable If is suspected that...

Page 13: ...essaging Telegram messaging or Webhooks Events that are in condition to send a message can be reviewed in a Board associated with your account in whose name the suffix Alarms is included To review an...

Page 14: ...ains the suffix Alarms This Dashboard will contain a table like the following To learn how to modify the elements and configuration of a Device refer to the manufacturer s guide provided for it Rememb...