Powered by
www.3sense.tech
Nov. 2018
This device is part of 3Sense product family
2.2. Mounting Indications
2.2.1. Main Unit
To secure main unit enclosure to a wall:
1.
Clean and prepare the surface on which the main unit will be placed, so that no grease or
liquid residues are left on it.
2.
Ad here the unit to this surface using the double-sided tape that the device has on its back
face.
It is more convenient to install the main unit before connecting the external sensor, if necessary;
however, the device can also be mounted with a peripheral connected without major
complications.
3. Electrical Installation Foreword
Consider implementing electrical safeguards independent to Pro-E 4.0 when designing the wiring
and grounding plans for your application. This helps to assure optimum system operation,
provides additional electrical noise protection for your application and the device; and prevents
any malfunction on the process to be managed due to unexpected operating failures, to which any
electronic system is susceptible.
3.1. Power Requirements
Among other hardware and firmware precautions, Pro-E 4.0 is protected against power
interruptions through its battery; which also protects monitoring and storage of data.
Battery can provide power for up to 24 hours, depending on the implemented external sensor.
Electrical Ratings:
•
Rated main input voltage:
5 VDC.
•
Max. Electric Current:
0.15 A.
•
Power Adapter:
Mini USB A/AB plug
.
Battery Ratings:
•
Rated Voltage:
3.7 VDC.
•
Power Rating:
1220 mAh.
•
Type:
LiPoly
.