background image

3

Please read these important safety instructions before commissioning!

Incorrect installation can cause serious personal injury and damage to property. 
The warranty claim expires in case of non-observance of this user information with all contained notes and regulations.
In case of non-observance of these instructions, the manufacturer or supplier shall not be liable for any personal injury or property damage incurred.

 SAFETY INSTRUCTIONS

GENERAL SAFETY INSTRUCTIONS

IMPROPER USE

This symbol indicates information about general danger. 

Non-observance can mean danger to 

persons and objects!

PROPER USE

This symbol indicates important information that can 

ensure safe and proper use of the device.

This symbol indicates danger due to electrical energy. 

Danger to persons and objects may arise if the 

associated information is not observed!  

 Danger to life from electric shock when working on electrical equipment. 

 The electrical connection, installation and commissioning of the receiver may only be carried out 

   by qualified personnel.  

 The timer may only be installed and connected in a de-energized state.

 The relevant regulations and guidelines must be followed without fail, to avoid damage to persons and objects.

 Observe safety instructions according to EN 60 335-2-97: The power supply cable of the drives must be laid internally.

 Installation according to DIN 18073: The roller shutter box cover must be easily accessible and removable.

 Installation according to EN 60335: Only switches / pushbuttons / switching devices with a minimum contact opening 

  of 3 mm may be used. Furthermore the up and down direction must be interlocked against each other.

 When installing in damp rooms, observe regulations (VDE 0100, part 701 and 702).

 These drives can be connected in parallel without an isolating relay or central control. 

   In this case, the max. output power of the command transmitter (timer or otherwise) must be observed.

 Do not use defective devices: Never use defective equipment.

  Periodically inspect the equipment for imbalance and signs of wear or damage to cables and suspension springs. 
  Do not use equipment if repair or rework is necessary.
  There is a risk of personal injury and property damage due to electric shock or short circuit.

 Retain the instructions for future reference.

 Persons are to be instructed with the correct operation of the tubular motor. 

 The roller shutter movement must be monitored in order not to endanger persons. 

 Do not allow children to play with motor controls.

 Store the handheld transmitter in such a way that unintentional operation is prevented (e.g. by children playing).

 The device can be used by children aged 8 years and above and persons with reduced physical, sensory or mental 

  capabilities or lack of experience and knowledge, if they have been given supervision and instruction concerning use 
  of the appliance in a safe way and are aware of the hazards involved.

 Children are not allowed to play with the equipment.

 If the power supply cord of this device is damaged, it must be replaced by the manufacturer or its customer service 

  or a similarly qualified person to prevent hazards.

 Use tubular motors only for automating shutters.

 Only use original components and original accessories from the manufacturer. 

 The mains connection cable of the drives must be laid internally in the empty conduit up to the junction box. 

  The local electrical regulations must be observed.

 For the electrical connection of the tubular motors, a 230 V / 50 Hz 

  power connection with fuse must be available at the installation site.

3T-MOTORS Tubular motors

  |  Safety instructions

Summary of Contents for 3T-MOTORS 3T45-E

Page 1: ...0E 3T45 30E 3T45 40E www 3t components de WEEE Reg Nr DE 77028333 INTELLIGENT DRIVES CONTROLS FOR SHUTTERS AND AWNINGS INSTALLATION OPERATING INSTRUCTIONS Instructions and notes for installation and o...

Page 2: ...ge 8 7 Setting the end positions Page 9 Troubleshooting What to do when Page 10 Position of the anti lift devices Page 10 EU Declaration of Conformity Page 11 Hotline 06732 600 0369 3T MOTORS Tubular...

Page 3: ...ulations VDE 0100 part 701 and 702 These drives can be connected in parallel without an isolating relay or central control In this case the max output power of the command transmitter timer or otherwi...

Page 4: ...0 Nm 37 kg 8 m 7 m 190 W 17 U min 3 min 230 V 639 mm 617 mm 2 5 m 4 min IP44 4260336113065 3T45 30E 30 Nm 56 kg 12 m 11 m 240 W 17 U min 3 min 230 V 669 mm 647 mm 2 5 m 4 min IP44 4260336113072 3T45 4...

Page 5: ...motor is designed for short time operation 4 min It has an internal thermal circuit breaker which interrupts the power supply in the event of overheating e g as a result of continuous operation The c...

Page 6: ...SHUTTER MOTOR Installation situation 1 Counter bearing 2 Ball bearing 3 Roller capsule 4 Shutter shaft 5 Suspension spring 6 Shaft adapter 7 Tubular motor 8 Limit switch adapter 9 Engine mount 10 Shut...

Page 7: ...e roller shutter shaft is flush with the limit switch adapter motor head fig 3 9 3 10 4 Mount bearings Remove old wall bearing on motor side left or right installation possible Mount motor bearing at...

Page 8: ...s upstream and downstream leads brown black must be turned Roller capsule Wall bearing Ball bearing Shutter motor 230 V 50 Hz Power grid 230 V 50 Hz 1 brown black L1 Phase 2 blue N Neutral conductor 3...

Page 9: ...against the end stops but stops automatically beforehand Every 60 cycles the drive independently checks and corrects the end positions in fully automatic mode or Manual mode Suspension springs and no...

Page 10: ...ion Swap the two wires for the direction of rotation brown black the motor does not switch off at the set point Check fit of limit switch adapter must be flush with motor head and shutter shaft Roller...

Page 11: ...n Anforderungen der aufgef hrten EG EU Richtlinien erf llt 2014 35 EU Niederspannungsrichtlinie 2014 30 EU EMV Richtlinie 2011 65 EU RoHS Richtlinie 2012 19 EU WEEE Richtlinie angewandte Standards und...

Page 12: ...49 0 6732 600 03 69 Fax 49 0 6732 600 54 30 www 3t components de Opening hours Monday Friday 8 00 17 00 bit ly youtube 3TComponents Social Media Links Info news and tips on roller shutters awnings sma...

Reviews: