Windows Installation
48
3ware Escalade ATA RAID Controller User Guide
Reboot the machine
When you reboot the system, log in as system administrator.
Continue with the following steps to make any new disk arrays or
independent disks accessible to Windows 2000/XP/2003.
1
Remove the driver diskette, then select
Yes
to restart the system. The sys-
tem may not boot if you don’t remove the diskette.
2 Partition and format the new arrays or disks using
Disk Administrator
:
a
Choose
Administrative Tools
from the
Start
menu.
b
Choose
Computer Management
from the
Administrative Tools
menu.
c
Select
Storage.
d
Select
Disk Management.
5 Follow the steps the appear on-screen to write a signature to the drive.
6 Right click on the drive and select
Create Volume
.
7 Follow the steps the appear on-screen to create a volume and to assign a
drive letter.
RAID array initialization
RAID 0 arrays do not need to be initialized and are immediately available for
use with full performance when created.
RAID 1 and 10 arrays are not initialized when created and are immediately
available for use with full performance when created. The first time the array
is verified (via the BIOS or 3ware 3DM), the array is initialized. Initialization
results in data from one disk (the disk on the lower channel number) being
copied to the other drive. In RAID 10 arrays, data from one half of the array is
copied to the other half. After the initial verification, subsequent verifies to a
RAID 1 or 10 array result in the data from one drive (or set of drives) being
compared to the other drive (or set of drives).
RAID 5 arrays are immediately initialized after being created in the BIOS by
writing zeroes to all array members. The user can reboot the system before
this is complete in order to use the RAID 5 array immediately. Once booted to
the operating system, if the RAID 5 array was not fully initialized in the
BIOS, it goes into initialization mode after a delay of up to ten minutes. The
advantage of this procedure is that the RAID 5 array can be used immediately,
but it will not be fault tolerant until the initialization is complete. The
disadvantage of this is that it takes longer for the array to become fully
redundant, because it takes longer to initialize an array than it does to write
zeroes to the array.
Summary of Contents for 8006-2LP - Escalade RAID Controller
Page 6: ...iv 3ware Escalade ATA RAID Controller User Guide ...
Page 14: ...Before You Begin 6 3ware Escalade ATA RAID Controller User Guide ...
Page 24: ...Quick Installation Guide 16 3ware Escalade ATA RAID Controller User Guide ...
Page 68: ...Windows Installation 60 3ware Escalade ATA RAID Controller User Guide ...
Page 86: ...FreeBSD Installation 78 3ware Escalade ATA RAID Controller User Guide ...
Page 104: ...3DM Disk Management Utility 96 3ware Escalade ATA RAID Controller User Guide ...
Page 116: ...Troubleshooting Problems and Solutions 108 3ware Escalade ATA RAID Controller User Guide ...
Page 126: ...Index 118 3ware Escalade ATA RAID Controller User Guide ...