3DM 2 Reference
www.3ware.com
109
Serial Number
. Indicates the BBU serial number.
BBU Ready.
Indicates if the BBU is able to backup the 3ware RAID
controller or not. If the BBU is “Ready”, write cache can be enabled on the
3ware RAID controller. When the status is not “Ready,” write caching is
automatically disabled on all units attached to the controller.
BBU Status.
Indicates the status of the BBU. Possibly BBU statuses include
the following:
OK
. The BBU is functioning normally.
Not Present
. The BBU was not detected or is disabled. (The BBU can be
disabled using CLI.)
No Battery
. No battery pack is installed in the BBU.
Testing
. A battery capacity test is in process.
Charging
.The battery is being charged. Charging of the battery occurs
automatically if the battery voltage falls too low. This normally occurs
about once a week to top off the charge level; the process does not change
the BBU readiness state.
If the battery is ever discharged through a backup cycle or if the system
power is off for more than two weeks, the battery status changes to
“Charging” the next time the system is powered on. This indicates the
BBU is not able to backup the 3ware RAID controller. When the BBU is
in the charging state, write caching is disabled automatically on all units
attached to the controller.
Fault
.The BBU detected a fault. This occurs if the voltage or temperature
is outside the acceptable range.
Error
. Other BBU error. Please contact AMCC Technical Support.
Weak Battery
. The battery should be replaced soon.The results of a
battery health test or capacity test indicate that the battery is below the
warning threshold (48 hours).
Failed Battery
. The battery failed a test and must be replaced. A “Failed
Battery” status is displayed if the battery failed the health test or the
battery capacity is below the error threshold (24 hours). The battery must
be replaced.
Battery Voltage.
Indicates the voltage status of the battery. The BBU
measures and evaluates the battery voltage continuously. If the voltage falls
outside the normal range, warning or error level AENs are generated. In the
case of a voltage error the BBU status will change to “Fault” and the battery
will be disconnected electronically.
Battery Temperature
. Indicates the temperature status of the battery. The
BBU measures and evaluates the battery pack temperature continuously. If the
temperature falls outside the normal range, warning or error level AENs are
Summary of Contents for 9550SXU-16ML - Sata Rohs
Page 10: ...viii 3ware 9550SX Serial ATA RAID Controller User Guide...
Page 64: ...Chapter 4 Driver Installation 54 3ware 9550SX Serial ATA RAID Controller User Guide...
Page 74: ...Chapter 5 3ware BIOS Manager 2 3BM 2 64 3ware 9550SX Serial ATA RAID Controller User Guide...
Page 124: ...Chapter 6 3ware Disk Manager 3DM 2 114 3ware 9550SX Serial ATA RAID Controller User Guide...
Page 220: ...Chapter 10 Maintaining Your Controller 210 3ware 9550SX Serial ATA RAID Controller User Guide...
Page 246: ...Appendix A Glossary 236 3ware 9550SX Serial ATA RAID Controller User Guide...
Page 260: ...250 3ware 9550SX Serial ATA RAID Controller User Guide...