14
QSG-002
/
01-03-2017
eIDC Web Server: Single Door
Application
If the eIDC is to be used as a stand-alone unit for a single door (neither
infinias
Access or Supervisor Plus will be used), you can easily use
the eIDC’s built-in web server and quickly program the system.
1.
Open a standard Web browser.
2.
Type the IP address given by the eIDC into the address bar of the
browser, and then press Enter. The
Intelli-M
Supervisor (Web
Edition) screen appears.
3.
Click the “Click Here to Start” button. The login screen appears.
4.
Type
admin
(all lowercase) in the user name and password text
boxes (admin is the default value for both of these fields), and then
click the “Login” button.
5.
From the Event screen, click the “System” button to display the
“System Management” screen.
6.
Click the “Database Management” button.
7.
Click the “Load Default Configuration” button. (Click “OK” to close
any dialog boxes that appear.)
8.
After the device configuration is loaded, click the “Done” button.
9.
Click the “Card Holders” button and do the following:
a.
Add or Modify a card holder.
b.
Fill in the “Site code” field and the “Card code” field.
c.
Fill in the first name, last name, and company fields.
NOTE:
The “Master Privilege Group” provides unrestricted access
to the door and all services in the system. You can create additional
groups with different privilege credentials. Refer to the “Web
Interface User’s Guide” for additional information.
d. Click “OK” and then click the “Events” button.
10. Swipe the card at the active card reader to ensure the functionality
of the system. Access should be granted.
11. Repeat Step 9 for the access cards of additional personnel.