background image

 

User Manual | 

VISIX Time of Flight People Tracking Camera 

 

 

10385 Westmoor Drive, Suite 210, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

This manual applies to the following camera models:  

Camera Type 

Model 

VISIX Time of Flight People Tracking Camera 

VX-VTOF-01 

 
Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to 
contact your sales representative or a 3xLOGIC support representative. 

The content of this guide is subject to change without notice. The manual will be amended if there are 
any hardware updates or changes. 

Summary of Contents for VX-VTOF-01

Page 1: ...User Manual VISIX Time of Flight People Tracking Camera 10385 Westmoor Drive Suite 210 Westminster CO 80021 www 3xlogic com 877 3XLOGIC i VISIX Time of Flight People Tracking Camera User Manual...

Page 2: ...dels Camera Type Model VISIX Time of Flight People Tracking Camera VX VTOF 01 Thank you for purchasing our product If there are any questions or requests please do not hesitate to contact your sales r...

Page 3: ...e power source to ensure that it is within the specifications Refer to Electrical Characteristics on APPENDIX A SPECIFICATIONS RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF...

Page 4: ...TWORK 13 6 1 IDENTIFYING THE CAMERA IP ADDRESS 13 6 1 1 Manually Identify Camera IP Address MAC Address HEX Conversion 13 6 1 2 Automatically Identify Camera IP Address with 3xLOGIC Camera Setup Utili...

Page 5: ...Imaging Class 1 laser diode the illumination power of 800 mW and the wave length of 850 nm Monochrome image of 320x240 pixels with infra red Network 10 100 Base T Ethernet Integration Software Develop...

Page 6: ...ALLATION GUIDE INSTALLATION TEMPLATE LENS MAIN PAGE PACKAGE CONTENS LENS LED POSITION INSTALLATION Slide LOCKING MOUNT COVER STEP 2 STEP 3 Mount Cover STATUS POWER VCA INFORMATION INDICATOR STEP 1 Mou...

Page 7: ...e marked circle It forms a 3D image by working with the IR illuminators on its sides Laser Emitters Emits infrared lights Status Power LED The light indicates whether it is powered on and operating no...

Page 8: ...nstallation without Bracket Steps 1 Push the slides on both sides of the device to the other ends to detach the mount cover from the body 2 Separate the mount cover from the body like the image on the...

Page 9: ...LAN cable from the ceiling to the LAN connector on the device for the PoE connection 2 Connect the safety wire on the device to the safety wire bracket on the mount cover by referring to the image on...

Page 10: ...60 degrees V 46 degrees 4 2 Installation with Bracket There are optionally two accessories available to attach the device to an installation surface VX VTOF BPT Pan Tilt Bracket VX VTOF BPM Pendant M...

Page 11: ...bracket Using a pan tilt bracket is highly recommended to cover a wider viewing range wider FOV from the device Below are the instructions for the angle adjustment of the pan tilt bracket Tilt Loosen...

Page 12: ...com 877 3XLOGIC 12 5 Connections 1 LAN Connection This is an RJ45 LAN connector for 10 100 Base T Ethernet Use the Ethernet cable RJ45 to connect the device to a hub or a router in the network Refer t...

Page 13: ...a device s default IP address In case of generic private network environment where IP address 192 168 XXX XXX are used the following procedure can be used to identify a device s IP address Steps 1 Con...

Page 14: ...rk will be visible 2 To select a device click on the desired device in the generated menu under the Select Online Devices area 3 To change an IP address for a selected VISIX camera in the Detect Onlin...

Page 15: ...ws 7 Internet Explorer 9 environment 6 3 View Video Using 3xLOGIC Camera VSXIP Setup Utility To access a video preview via the 3xLOGIC Camera Setup Utility launch the utility and follow the below inst...

Page 16: ...t press the reset button for more than 2 seconds Otherwise the camera may be switched to its factory default settings 6 6 FACTORY DEFAULT Resetting the device back to the factory default will initiali...

Page 17: ...lick the Factory Default button Then the dialog box will appear to ask you if you want to reset all settings Click the OK button and wait until the Reset All Settings page is refreshed after the reboo...

Page 18: ...the main typical causes The power supply is continually unplugged certain times in the middle of system booting The firmware files required for system booting are damaged There are conflicts in the s...

Page 19: ...FUNCTION Operating Range 2m 8m 15 fps Coverage Area Top View TBD Side View Typical Floor Coverage 6m 4m Mounting Height 2m Ceiling Good Performance 3m 4m Optimal Performance Suitable Locations Indoors...

Page 20: ...1 lb 970 g Material Aluminum Die Casting Color Ivory VIDEO ANALYTICS High Performance Advanced tracking algorithm Easy to Use Intuitive interface Detection Zones and Rules 40 zones Multi segment Poly...

Page 21: ...3XLOGIC 21 VIDEO ANALYTICS Object Classification Configured Max Min object sizes and Max Min speeds People Tracking Tracks individuals separately among overlapped multiple people Counting Line High a...

Page 22: ...ble PoE has advantages over conventional power in such places where AC powers cannot be reached or is expensive to wire 8 1 Power Consumption Property 802 3af 802 3at Available Power 12 95 W 25 50 W M...

Page 23: ...User Manual VISIX Time of Flight People Tracking Camera 10385 Westmoor Drive Suite 210 Westminster CO 80021 www 3xlogic com 877 3XLOGIC 23 9 Appendix C Dimensions...

Page 24: ...A 234 0D 13 32 50 57 87 7C 124 A1 161 C6 198 EB 235 0E 14 33 51 58 88 7D 125 A2 162 C7 199 EC 236 0F 15 34 52 59 89 7E 126 A3 163 C8 200 ED 237 10 16 35 53 5A 90 7F 127 A4 164 C9 201 EE 238 11 17 36 5...

Page 25: ...16 3xLOGIC Inc All rights reserved Information in this document is subject to change without notice 3xLOGIC and the 3xLOGIC logo are trademarks of 3xLOGIC Inc All other trademarks are the property of...

Reviews: