background image

SHIPPING UNITS

Questions? Email: technical@475.supply |  Call: 800-995-6329

3

OPERATING CONDITIONS

ASSEMBLY – INSTALLATION PIPES

Check the shipment to 
ensure all items ordered 
have been received. Note 
any missing items or 
damages to 475 ASAP and 
include photos if possible.

Contact: info@475.supply

e

2

 :

 Installation pipe, exterior 

white grill, heat exchange unit, 
indoor cover, optional 
condensate ring, and 
installation instructions are 
supplied as a complete set.

e

2

 short:

 Installation pipe, 

exterior white grill, heat 
exchanger unit, indoor cover, 
optional condensate ring, and 
installation instructions are 
supplied as a complete set.

Indoor Cover

Heat Exchange Unit

Outside Grill

Installation Pipe

Make the wall openings for the assembly pipes 
(e.g. by coring, core bit Ø 6.37"/162mm). 

If necessary, shorten the pipe to the desired 
installation length 

e

2

 minimum 11.8"(300 mm): 

e

2

 short minimum 8" (200 mm)

Take care that the pipe extends on both sides for 
finishes (sheetrock plaster, siding) with finishes 
Installed flush with the pipe. 

Insert the pipe, with a min. 3/8:12 (3mm) pitch 
and airseal it with ROFLEX 150 gaskets, 
TESCON tapes or other airtight solutions.

Summary of Contents for e2

Page 1: ...ol is a danger warning in connection with risk of injury from electricity Safety instructions Beware Any assembly work to the ventilation device may only be carried out after disconnecting all phases...

Page 2: ...volume is equal to the total exhausted volume If a pair of fans in this balanced push pull operation is installed in two different rooms of a dwelling a sufficiently dimensioned interconnection under...

Page 3: ...llation pipe exterior white grill heat exchanger unit indoor cover optional condensate ring and installation instructions are supplied as a complete set Indoor Cover Heat Exchange Unit Outside Grill I...

Page 4: ...terior grill finishes are also available in stainless steel grey burgundy and white Safety Instructions Beware Any assembly work to the ventilation device may only be carried out when all of the suppl...

Page 5: ...or the supply voltage to the transformer power supply unit 14 gauge Double Rocker Switch Connection W1 W2 grey red black Rocker switch front view Rotary Switch Connection grey red black Device connect...

Page 6: ...lter casing snap the interior blind into place in open position off wall If cover completed covered lift cover and rotate 180 Installation is now complete When operating the Lunos e2 using a double ro...

Page 7: ...5 supply Call 800 995 6329 Exhaust air without heat recovery Unpaired operation with 1 unit connected to S1 and two units connected to S2 7 The LED will permanently light in red when the lter is due t...

Reviews: