ASSEMBLY– VENTILATION INSERT AND INDOOR ROOM COVER

Questions? Email: technical@475.supply |  Call: 800-995-6329

OPERATION

6

Remove interior protection lid cover, insert heat 
exchange unit into the installation pipe, ensure there is 
a ⅞" gap on interior of pipe. Motor/fan faces interior. 

The loop on fan unit can be used to pull unit for 
maintenance.

Connect wiring to plug. Connect plug into socket and 
set them into the recess of the heat exchanger casing.

Insert interior cover with filter casing, snap the interior 
blind into place in open position (¼” off wall).

If cover completed covered, lift cover and rotate 180°. 
Installation is now complete.

When operating the Lunos e

2

 using a double-rocker 

switch, apply the provided sticker to the switch plate 
as shown. The markings on the sticker correspond to 
the following:

Both W1 + W2 OFF

= Level 0

Switch W1 ON 

= Level I

Switch W2 ON 

= Level II

Both W1 + W2 ON 

= Level III

When operating the Lunos e

2

 with the optional 475 

Rotary Switch, the switch positions correspond to 
the following (assume a clock face):

12:00 (position 0)

= Level 0

1:00 (position 1) 

= Level I

2:00 (position 2) 

= Level II

3:00 (position 3) 

= Level III

W1

W2

Sticker placement

Summary of Contents for e2

Page 1: ...ol is a danger warning in connection with risk of injury from electricity Safety instructions Beware Any assembly work to the ventilation device may only be carried out after disconnecting all phases...

Page 2: ...volume is equal to the total exhausted volume If a pair of fans in this balanced push pull operation is installed in two different rooms of a dwelling a sufficiently dimensioned interconnection under...

Page 3: ...llation pipe exterior white grill heat exchanger unit indoor cover optional condensate ring and installation instructions are supplied as a complete set Indoor Cover Heat Exchange Unit Outside Grill I...

Page 4: ...terior grill finishes are also available in stainless steel grey burgundy and white Safety Instructions Beware Any assembly work to the ventilation device may only be carried out when all of the suppl...

Page 5: ...or the supply voltage to the transformer power supply unit 14 gauge Double Rocker Switch Connection W1 W2 grey red black Rocker switch front view Rotary Switch Connection grey red black Device connect...

Page 6: ...lter casing snap the interior blind into place in open position off wall If cover completed covered lift cover and rotate 180 Installation is now complete When operating the Lunos e2 using a double ro...

Page 7: ...5 supply Call 800 995 6329 Exhaust air without heat recovery Unpaired operation with 1 unit connected to S1 and two units connected to S2 7 The LED will permanently light in red when the lter is due t...

Reviews: