When the ETH-SWITCH has power, the POWER LED will illuminate red.  Each Port on the switch has 

a green LED.  When a cable is plugged into the port, the LED will illuminate solid green.  When there is 

Ethernet activity on the port, the LED will flash green.

9. TROUBLESHOOTING GUIDE

CONDITION

SOLUTION

Power LED is Off

1. Check that power is applied to the input terminal and polarity is 

correct.

2. Check that the fuse F5 is not damaged

Network  Communications      

is  not working

1. Check that the Power LED is on

2. 

Check that the activity LED is on / flashing

3. 

Check IP configuration of devices

Activity LED is off

1. Check that the Power LED is on

2. Check that the RJ-45 connector is fully seated in the socket

3. 

Check that the CAT5/CAT6 cable is following the T568A or T568B standard

Red Power LED - On

Green Port LED On - Cable Is Plugged Into The Port
Green Port LED Flashing - Ethernet Activity On The Port 

Port LED Off – Cable Unplugged From The Port

Image 3

Image 2

Summary of Contents for ETH-SWITCH1V4C-5P

Page 1: ...www go4b com usa Industrial Ethernet Switch INSTALLATION INSTRUCTIONS OPERATION MANUAL Part No ETH SWITCH1V4C 5P APPROVED Class II Div 1 C US Industrial Ethernet Switch ...

Page 2: ...arts will cause severe injury or death Lockout power before removing cover or inspection door DANGER DANGER Moving parts can crush and cut Lockout power before removing guard or servicing Do NOT operate with guard removed WARNING ...

Page 3: ...TION Page 7 6 ELECTRICAL CONNECTION Page 8 7 WIRING DIAGRAMS Page 10 7 1 SUPPLY VOLTAGE WIRING 24 VDC Page 10 7 2 NETWORK BLOCK DIAGRAM Page 10 8 IE SWITCH OPERATION Page 11 9 TROUBLESHOOTING GUIDE Page 11 10 TESTING AND MAINTENANCE Page 12 11 WARNINGS PRESENT ON PRODUCT Page 12 12 PRODUCT WARRANTY Page 15 TABLE OF CONTENTS ...

Page 4: ...ional Electrical Codes and other standards applicable to your industry Please see the article Hazard Monitoring Equipment Selection Installation and Maintenance at www go4b com The installation of the wiring should be undertaken by an experienced and qualified professional electrician Failure to correctly wire any product and or machinery can result in the product or machine failing to operate as ...

Page 5: ...ction work at the facility hours of operation animal or insect infestation and the real world experience of knowing how your employees perform their jobs The personnel or person you select to install operate maintain inspect or perform any work whatsoever should be trained and qualified to perform these important functions Complete and accurate records of the maintenance and inspection process sho...

Page 6: ... Ø 1 1 8 x 2 Ø 5 16 x 4 8 13 16 9 3 4 5 1 4 3 SPECIFICATIONS Supply Voltage 24 VDC Power Dissipation 12 Watts Maximum Power Terminals 14 AWG 2 5 mm2 Communication Protocols PROFINET EtherNet IP Modbus TCP IP or any other Ethernet protocol Inputs 5x RJ 45 10 100 Mbps Width 7 4 in 188 mm Depth 4 in 102 mm Height 9 7 in 246 mm Fixing Centers 8 75 x 4 in 222 x 102 mm Cable Entry 2 Holes 1 1 8 in 28 mm...

Page 7: ...ed in a Class II environment Power input and output I O wiring shall be in accordance with Class II wiring methods per the National Electrical Code NFPA70 for installations within the US and per the Canadian Electrical Code CEC for installations in Canada 6 The voltage current and maximum power dissipation on the units label must not be exceeded 7 The wiring installation must extend to within 1 mm...

Page 8: ...f 158 F 70 C or above and be at least 24 AWG 4B recommends using shielded cable to reduce electromagnetic interference EMI to maintain signal integrity Never run low voltage cables in the same conduit as three phase motor cables Use rigid metal conduit to protect the cables coming into the Ethernet Switch Conduit systems can channel water due to ingress and condensation which over time will advers...

Page 9: ...PAGE 9 Output 4 Output 2 Output 3 Output 1 Input Power Earth Ground Image 1 ...

Page 10: ... NODE 0002 NODE 0003 256 Nodes Per Network Over 4 000 Sensors Optional Hazardmon com Connection Eth Switch 1 Ethernet Cable Ethernet Cable PLC Eth Switch 2 IE NODE 1 8 Contact or NTC Temperature and 2 Pulse or Analog 4 20 mA inputs IE NODE 2 10 Analog 4 20 mA Inputs with ETH NODE AUXSW 4P 24V 0V 24V 0V 24V 0V 24V 0V 24V 0V Output 4 Output 2 Output 3 Output 1 Input Power Earth Ground ...

Page 11: ...al and polarity is correct 2 Check that the fuse F5 is not damaged Network Communications is not working 1 Check that the Power LED is on 2 Check that the activity LED is on flashing 3 Check IP configuration of devices Activity LED is off 1 Check that the Power LED is on 2 Check that the RJ 45 connector is fully seated in the socket 3 Check that the CAT5 CAT6 cable is following the T568A or T568B ...

Page 12: ...tured by Don Electronics Limited Westfield Industrial Estate Kirk Lane Yeadon Leeds LS19 7LX United Kingdom WARNING If the system does not immediately shutdown as expected or alarm as required then remove the machine from service until the problem has been diagnosed and corrected 10 TESTING AND MAINTENANCE Below is the procedure that the end user must adhere to in order to maintain the system in a...

Page 13: ...PAGE 13 END USER NOTES ...

Page 14: ...PAGE 14 END USER NOTES ...

Page 15: ...SE OR MISAPPLICATIONS AS AUTHORIZED BY LAW 4B SPECIFICALLY DISCLAIMS ALL WARRANTIES THAT THE PRODUCT IS FIT OR MERCHANTABLE FOR A PARTICULAR PURPOSE 3 NO WARRANTY BY SAMPLE OR EXAMPLE ALTHOUGH 4B HAS USED REASONABLE EFFORTS TO ACCURATELY ILLUSTRATE AND DESCRIBE THE PRODUCTS IN ITS CATALOGS LITERATURE AND WEBSITES SUCH ILLUSTRATIONS AND DESCRIPTIONS ARE FOR THE SOLE PURPOSE OF PRODUCT IDENTIFICATIO...

Page 16: ...6114 4B AUSTRALIA Building 1 41 Bellrick Street Acacia Ridge 4110 Queensland Australia Tel 61 7 3216 9365 4B COMPONENTS LTD 625 Erie Avenue Morton IL 61550 USA Tel 309 698 5611 Fax 309 698 5615 4B BRAIME COMPONENTS LTD Hunslet Road Leeds LS10 1JZ United Kingdom Tel 44 113 246 1800 Fax 44 113 243 5021 4B DEUTSCHLAND 9 Route de Corbie Lamotte Warfusée F 80800 France Tel 49 700 2242 4091 Fax 49 700 2...

Reviews: