background image

www.go4b.com/usa

WDA Sensor

BELT ALIGNMENT / MOTION & 
BROKEN / SLACK CHAIN MONITOR

INSTALLATION INSTRUCTIONS

OPERATION MANUAL

Part No. WDA3V34C

APPROVED

Class II Div. 1

C

US

®

Summary of Contents for HTAS1V34

Page 1: ...www go4b com usa WDA Sensor BELT ALIGNMENT MOTION BROKEN SLACK CHAIN MONITOR INSTALLATION INSTRUCTIONS OPERATION MANUAL Part No WDA3V34C APPROVED Class II Div 1 C US...

Page 2: ...l cause severe injury or death Lockout power before removing cover or inspection door DANGER Exposed buckets and moving parts will cause severe injury or death Lockout power before removing cover or i...

Page 3: ...DIMENSIONS Page 7 INSTALLATION BUCKET ELEVATOR Page 8 BUCKET ELEVATOR PLACEMENT DIAGRAMS Page 9 12 INSTALLATION CONVEYORS Page 13 14 STANDARD WIRING DIAGRAMS Page 15 16 TESTING COMMISSIONING Page 17 S...

Page 4: ...asked 4B to perform these tasks B All installation and wiring must be in accordance with Local and National Electrical Codes and other standards applicable to your industry Please see the article Haz...

Page 5: ...tion work at the facility hours of operation animal or insect infestation and the real world experience of knowing how your employees perform their jobs The personnel or person you select to install o...

Page 6: ...uminium The WDA can detect ferrous steel elevator buckets from the side of the elevator leg or through the elevator belt from the back of the leg For plastic elevator buckets the steel elevator bolts...

Page 7: ...ometer Sensing Range Adjustment Screw 9 ft Cable ALL DIMENSIONS IN INCHES 4 1 16 3 7 16 4 1 16 3 7 16 1 5 16 x 4 2 6 1 16 5 3 16 7 8 2 LED 1 2 Inch NPT Threaded Entry Sensor Depth Adjustment Bolt Sens...

Page 8: ...al or use the bracket itself by centering on the existing 2 1 4 inch 57 mm hole For side mounting of steel buckets Option 1 make sure that the belt is centered on the pulley and install a sensor on ea...

Page 9: ...vator leg to target the elevator bolts used to secure the plastic buckets Figure 6 X X Mount WDA sensor within a few feet of the pulley or as close to this position as possible Figure 1 Typical WDA Se...

Page 10: ...buckets and bolts non ferrous use PTFE coated steel fender washers ferrous between the belt and bucket Mount WDA sensor on the back side of the leg to target the ferrous bolts washers Alternatively 40...

Page 11: ...NTING DIAGRAMS METAL ELEVATOR BUCKETS WITH CLOSE VERTICAL CENTERS Figure 5 illustrates the optimal WDA sensor placement for elevator buckets with close vertical spacing This placement allows for the m...

Page 12: ...Of Leg 1 2 in to 1 in Plastic Elevator Bucket Approximately 1 1 2 inches Bolt Head Elevator Trunking WDA Mounting Block WDA Sensor Potentiometer Sensing Range Adjustment Screw Figure 7 WDA Sensor Inst...

Page 13: ...ng for the sensor or the mount can be installed on a stainless steel plate welded directly to the conveyor housing over the hole Since stainless steel is non ferrous the sensor will not be affected as...

Page 14: ...lt passes through the sensor s field and a pulse is sent to the speed relay If the chain becomes slack the target bolt will drop below the field and the pulses will stop causing the relay contact to c...

Page 15: ...ody the wiring process is outline below RED BROWN Supply VDC BLACK BLUE Supply VDC GREEN GREEN Ground YELLOW ORANGE Control BLUE BLACK Pulsed Output WHITE Continuous Output WDA3 WDA1 To use the intern...

Page 16: ...d installation information WDA Sensor 1 2 3 4 5 6 7 8 9 10 11 12 Speed Relay Control Module SR2V5 1 X WHITE ORANGE RED BLUE BLACK GREEN N L Fuse 2A 110 VAC When Running 0 VAC When Stopped 110 VAC Supp...

Page 17: ...ler WARNING If the system does not alarm as required then remove the machine from service until the problem has been diagnosed and corrected TESTING AND COMMISSIONING 1 Check that the unit is correctl...

Page 18: ...aring temperature pulley alignment and plugged condition monitoring for bucket elevators and conveyors A 3 5 LCD screen displays the entire system status at a glance WDA High Temperature Sensor HTAS1V...

Page 19: ...DUE TO PRODUCT MISUSE ABUSE OR MISAPPLICATIONS AS AUTHORIZED BY LAW 4B SPECIFICALLY DISCLAIMS ALL WARRANTIES THAT THE PRODUCT IS FIT OR MERCHANTABLE FOR A PARTICULAR PURPOSE 3 NO WARRANTY BY SAMPLE OR...

Page 20: ...frica Tel 27 0 11 708 6114 Fax 27 0 11 708 1654 4B AUSTRALIA Unit 1 18 Overlord Place Acacia Ridge Queensland 4110 Australia Tel 61 0 7 3711 2565 Fax 61 0 7 3711 2574 4B COMPONENTS LTD 625 Erie Avenue...

Reviews: