14
UP
RADIO SET
FORCE
Auto-closing timer is turned off as default (the screw control is at fully “-” )
1. Optional Photo Eye* must be selected and properly connected and aligned to enable Auto
-Closing Operation. (* Contact your local operator supplier)
2. Turn the screw towards ‘+’ position to set to appropriate delay time (max. 2-1/2 minutes)
for the door to auto-close after fully opened.
3. When the delay time is reached within the door at fully open position, the operator beeps
twice and closes the door automatically.
1
2
3
4
x2
Photo Eye must be selected and connected
S
ETTING
A
UTO-
C
LOSING
Operation
/
Courtesy Light / Buzzer Responses
Operation / Condition
Operator is initially plugged-in (no travel limits stored)
Flash x 5
Reconnecting power (with travel limits stored)
Flash x 3
“RADIO SET” button is pressed
Beep x 1
Upon activation
Light On for 2.5 minutes
Upon activation by remote transmitters
Beep x 1, Light On for 2.5 minutes
Remote Transmitter / Keyless Entry PIN code accepted
Beep x 2
Operator is triggered without programming
Beep x 5
Door travels with abnormal speed
Beep x 12 (1 beep / second)
Photo Eye System is obstructed during door-closing
Beep x 20 Medium Beep
The door is obstructed during travel
Beep x 25 Rapid Beep
Courtesy Light / Beeper Responses
Courtesy Light / Beeper Responses
Photo Eye Selection
Jumper off — Selected
Jumper on — Unselected