movement. The power supply terminals for the photocells are
protected by an electronic fuse which cuts off the supply in the
event of an overload.
• Connect the transmitter power supply to terminals
E2
and
E3
of the control.
• Connect the receiver power supply to terminals
E1
and
E2
of
the control.
• Connect the fl oating normally closed contact of the receiver
type 1
to terminals
J5
and
J9
of the control.
• Connect the fl oating normally closed contact of the receiver
type 2
to terminals
J6
and
J9
of the control.
• Activate testing in menu
P32
.
18
1
J
2
J
3
J
4
J
5
J
6
J
7
J
8
J
9
J
E5
E3 E4
E2
E1
Figure 18 - Connecting the light barriers
Note
In the event that multiple pairs of photocells of the same type
(type 1/type 2) are installed, their normally closed contacts
must be connected in series.
If a refl ection light barrier is used, connect the power supply
to terminals
E2
and
E3
of the control so that testing can be
activated.
5.8
Closing edge protection
Two inputs are available for connection of safety contact strips:
Safety contact strip type 1 (terminals J7 and J9)
:
The input is only active in the open direction. In the event that the
closing edge protection is actuated during opening, the opener
stops and runs for approx.
3 sec
. in the opposite direction.
The next start command and/or expiry of the hold-open time (with
automatic gate closing activated) closes the gate.
Safety contact strip type 2 (terminals J8 and J9)
:
The input is only active in close direction. In the event that the
closing edge protection is actuated during closing, the opener
stops and runs for approx.
3 sec
. in the open direction, with
automatic gate closing activated, the gate opens fully.
In the event that the closing edge protection is actuated 5x in a
row with automatic gate closing set, the gate remains open and
closes only when a new start command is given.
Note
The evaluation function can be selected in menu
P35
.
The following settings are possible:
• Evaluation for 8k2 safety contact strips
• Evaluation for external evaluation devices with normally
closed contact and testing
• Evaluation for external evaluation devices with normally
closed contact without testing
• Connect the 8k2 edge protection fuse or fl oating normally
closed contact of the safety strip evaluation device
type 1
to
terminals
J7
and
J9
of the control.
• Connect the 8k2 edge protection fuse or fl oating normally
closed contact of the safety strip evaluation device
type 2
to
terminals
J8
and
J9
of the control.
• Connect the power supply
24 V DC
of an external evaluation
device to terminals
E2
and
E3
of the control, this briefl y
switches off the voltage as a test.. If evaluation is used that
cannot be tested in this way, connect the power supply
24 V
DC
to terminals
E1
and
E2
.
19
1
J
2
J
3
J
4
J
5
J
6
J
7
J
8
J
9
J
E5
E3 E4
E2
E1
Figure 19 - Connecting the closing edge protection
Note
Closing edge protection fuses and associated evaluation
devices must satisfy
DIN EN 12978
.
5.9
Radio receiver
A receiver with 4-pin stud terminal (e.g. BDE221) may be clipped
onto the supplied adapter.
Note
Switch of the mains supply before connecting the radio
receiver! To program the radio kit, read the manual for the
receiver and handheld transmitter.
Adapter assignment
:
20
0 V DC
21
Channel 1 (start)
5
+ 12 V DC
23
Channel 2 (start P)
20
B1
Funk-Stecksockel
5
6
J
7
J
8
J
9
J
E5
E3 E4
E2
E1
RECEIVER
Adapter
Funk-Stecksockel
20
21
5
23
Figure 20 - Connecting the radio