12 ERROR TABLE
Display
(fl ashing) Info
Error/warning
Possible cause
Remedy
F01
Message appears after
exiting programming
mode.
Error, memory mode
The control
cannot
save the changes.
This malfunction cannot be rectifi ed on site.
Replace control or send for repair.
F02
Message appears after
a start command.
Error, motor triac.
Motor connection cable defective.
Check motor connection cable.
Control defective.
Replace control or send for repair.
F03
Teach-in of operating
times is
not
started or
interrupted.
Confi guration of the
control is unsuitable for
performing self teach-in.
The start inputs are not programmed as
default.
Set menu
P28
to
Stan
, see also
7.22 on
page 23
.
A safety device was triggered during
teach-in or has been activated in the
menu but is not connected.
Check safety devices or deactivate during
teach-in.
The ADI interface is activated.
Set menu
P46
to
nEin
, see also
7.37 on
page 27
.
F04
Message appears after
a start command.
Error, limit switch.
The opener has been released.
Lock opener, see.
The opener was released in an end
position and engaged again at the other
end position without the mains supply
being switched off .
Briefl y switch off mains supply. See also
10.5 on page 31
.
Incorrect arrangement of end position
magnets
Check arrangement of end position
magnets (blue = right, red = left), change
positions if necessary.
End position magnet distance too large.
To check, release opener, slide gate to
open or closed end position and monitor
control display. In intermediate position =
both bars at top, left magnet in front of reed
contact = last bar at bottom, right magnet
in front of reed contact = penultimate bar at
bottom. See ...
Check distance between end magnets,
check reed contact and adjust if necessary,
max. distance 38 mm.
Reed contact or reed contact connection
line defective.
Check for damage to connection line or
improper connection to control. Replace
reed contact if necessary.
Control defective.
Send control for repair or replace.
F05
Message appears after
a start command or
when gate moving.
Stop circuit was active.
Stop or emergency stop circuit at
terminals J3 and J4 was interrupted or
opened when the gate was moving, see
"5.6 Stop input" on page 14.
Close stop circuit. If no stop circuit
(terminals J3/J4) is connected, a wire
jumper must be connected between
terminals J3 and J4 or menu
P29
must be
set to
AUS
.
Note:
The automatic gate closing function is locked when the stop circuit is actuated and must be restarted by a start command.
F07
Message appears when
attempting to start
programming mode.
Control settings cannot
be modifi ed.
Control confi guration mode is locked.
To unlock, the programming key with which
the control was locked is required. This
must be inserted into the "
ADI
" interface.
F08
Message appears after
a start command in
close direction or during
closing.
CLOSE light barrier was
active.
Light barrier at terminals J6 and J9
was interrupted or actuated, see
"7.25
Photocell 2 input (terminals J6/J9)" on
page 24
.
Remove obstacle which triggered the light
barrier and/or check and replace the light
barrier if necessary.
When no light barrier is connected, menu
P31
must be set to
AUS
.
F09
Message appears after
a start command in
close direction.
CLOSE closing edge
protection was active.
Closing edge protection at terminals
J8 and J9 was interrupted or actuated,
see
"7.28 Closing edge protection
2 (terminals J8/J9) input" on page
25
.
Remove obstacle which triggered the
closing edge protection and/or check and
replace the closing edge protection/supply
line if necessary.
When no closing edge protection is
connected, menu
P34
must be set to
nEin
.
Incorrect evaluation activated, see
"7.29 Evaluation of the closing edge
protection" on page 25
.
Set correct evaluation in menu
P35
.
F11
Message appears after
a start command.
Error, encoder.
The connection to the encoder has been
interrupted or the encoder is damaged.
Check connection or replace encoder.
F12
Message appears after
a start command.
Thermal protection.
Opener thermal protection has triggered. Allow motor to cool and check function
again.
F13
Message appears after
a start command.
Error when testing ADI
module.
Loose ADI module connection or module
defective
Check plug connection and replace ADI
module if necessary.
Summary of Contents for CX1024
Page 1: ...www 4ddoors com au instructions for fitting operating and maintenance Sliding operator CX1024 ...
Page 2: ...2 A B Ø 12 mm Ø 5 5 mm 17 mm 3 mm 2 17 5 mm 3 mm PIC 01 ...
Page 12: ...ENGLISH 12 DX SX DX SX 11 Figure 11 End positions Max 38 mm 102 mm 12 Figure 12 Distances ...
Page 37: ...ENGLISH 37 ...