HMI Setup
TEMPERATURE CONTROL INSTALLATION
— OPTIONAL
1. Mount the temperature control unit to the
factory supplied junction box.
The junction box is inside the building 60”
above the floor.
Temperature/Humidity Control Wiring
.
WIND CONTROL INSTALLATION —
OPTIONAL
NOTE:
The Wind Control option requires the use of an
anemometer supplied by 4FRONT (6020770).
1. Attach a 3/4” schedule 40 pipe (1.06” dia.)
or 1” dia. structural pipe fitting to the outside
of the structure so that it protrudes no less
than 24” above the highest peak of the
structure.
This hardware is supplied by others.
2. Mount the wind speed/direction sensor to
the pipe.
You can pass the data cable through the
center of the mounting pipe or the outside of
the mounting pipe.
3. Route the data cable and terminate it at the
VFD box.
If a longer data cable is required, use
Belden 8723 or equivalent to extend the
length.