Aprisa SR+ Quick Start Guide 1.4.0 © 2018 4RF Limited. All rights reserved. This document is protected by copyright belonging to 4RF Limited and may 
not be reproduced or republished in whole or part in any form without the prior written permission of 4RF Limited. While every precaution has been 
taken  in  the  preparation  of  this  literature,  4RF  Limited  assumes  no  liability  or  errors  and  omissions,  or  from  any  damages  resulting  from  use  of  this 
information.  The  contents  and  any  product  specifications  within  it  are  subject  to  revision  due  to  ongoing  product  improvements  and  may  change 
without notice. Aprisa and the 4RF logo are trademarks of 4RF Limited. All other marks are the property of their respective owners. 

 

5. Set up the Aprisa SR+ radio 

The  Aprisa  SR+  has  a  factory  default  Terminal  Operating  Mode  of 
Remote Station. 

One radio in the Aprisa SR+ network must be setup as a Base Station. 

The  other  radios  in  the  Aprisa  SR+  network  are  setup  as  Remote 
Stations or Repeater Stations.  

Set the Ethernet Operating Mode. 

 

Set  the  unique  radio  Network  ID  to  be  the  same  in  your  entire 
network including the Base Station ID. 

 

Set  the  Aprisa  SR+  TX  Frequency,  RX  Frequency,  TX  Power  and 
Channel Size to comply with your site license. 

Set the Antenna Port Configuration required. 

 

 

You can now configure the remaining terminal and network parameters and settings. Please refer to the Aprisa SR+ User Manual for detailed 
instructions. For ACM implementations, we recommend that the Default Modulation be set to QPSK (Low Gain). 

 

6. Monitor the Aprisa SR+ radio signal strength 

When the network is installed, the radio signal strength can be monitored on 
remote stations by setting the radio to Test Mode. 

To  enter  Test  Mode,  press  and  hold  the  TEST  button  on  the  radio  LED  panel 
until all the LEDs flash green (about 3 - 5 seconds). 

In Test Mode, the LED Display panel presents a real time visual display of the 
RSSI. This can be used to adjust the antenna for optimum signal strength. 

Note: The response time is variable and can be up to 5 seconds. 

To exit Test Mode, press and hold the TEST button until all the LEDs flash red 
(about 3 - 5seconds). 

The OK, MODE and AUX LEDs will be solid green and the TX and RX LEDs will 
be solid or flash green if the network is operating correctly. 

 

 

For more information, please refer to the Aprisa SR+ User Manual available from the 4RF website www.4rf.com/secure/ (login required). 

 

 

 

 

 

 

 

Quick Start Guide 

 
 
 

Aprisa SR+ Radio 

 

Contents 

 

Follow these steps to operate your Aprisa SR+ radio: 

 

1.

 

Check the box contents 

2.

 

Install the Aprisa SR+ radio and connect the protection earth 

3.

 

Connect the Antenna and apply power to the Aprisa SR+ radio 

4.

 

Connect to the Aprisa SR+ radio 

5.

 

Set up the Aprisa SR+ radio 

6.

 

Monitor the Aprisa SR+ radio signal strength 

 

Reviews: