| 5
Aprisa SR+ User Manual 1.11.1
Short Range Device
When operating as a short range device under EN 300 220-2 V3.2.1 for Ofcom IR2030/2/6 or IR2030/2/7:
1. The user must operate the Aprisa SR+ radio within all the applicable requirements of IR-2030
2. The transmitter power must not be set above +27 dBm
When operating as a short range device, the Aprisa SR+ radio TX power can be adjusted over the range of
+10 dBm to +27 dBm (average power).
To determine the maximum power to be set on the Aprisa SR+ radio, it is necessary to take into account the
feeder loss and antenna gain.
1.
ERP limit (specified in dBm, in the case of IR-2030 this is +27 dBm)
ERP
dBm
2.
Peak to average power ratio
Px
dB
QPSK
3 dB
16QAM
5 dB
64QAM
6 dB
ACM
6 dB
3.
Antenna gain specified in dBd (if given in dBi subtract 2.15 dB from the given value)
G
dBd
4.
Feeder coax loss between Aprisa SR+ radio and antenna (specified in dB/m)
L
dB/m
5.
Length of feeder coax between Aprisa SR+ radio and antenna (specified in metres)
d
m
From the above information, the power setting of the Aprisa SR+ radio (P
dBm
) can be calculated to ensure
operation within the regulatory requirements using the formula:
P
dBm
= ERP
dBm
+ (d
m
x L
dB/m
) - G
dBd
- Px
dB
Summary of Contents for Aprisa SR+
Page 1: ...January 2021 Version 1 11 1b ...
Page 2: ......
Page 10: ......
Page 72: ......
Page 86: ......