SPECIFCATIONS
Motor: 12 Volt DC
Fuse: 45 Amp
Maximum re-start pressure: 90 psi
Maximum continuous operating time is 20 minutes
This air compressor is designed to run on a 12 Volt DC battery
MAINTENANCE AND CLEANING
We recommend that only qualified persons perform maintenance and
servicing on the air compressor.
NOTE: Always unplug or shut down your compressor before attempting
any type of maintenance. Wait for compressor to cool before servicing.
Ensure the unit has been switched off and has cooled down completely
before cleaning.
• Never immurse this unit in water.
• Simply wipe down with a soft cloth.
• IF THE UNIT STOPS
DURING OPERATION
1.
Check the battery condition. Low voltage can trip
the circuit breaker or trigger the protection feature.
2.
Check the circuit breaker, reset if necessary.
3.
The unit is equipped with an automatic protection
device. In the event the unit reaches an unsafe
operating temperature, a protection circuit will cut
power to prevent damage to the unit. If the
protection circuit activates, immediately disconnect
the unit from the power source and allow it to cool.
TROUBLESHOOTING
CAUTION
• Small items will inflate quickly and can easily be damaged. Pay
special attention to bicycle tyres. They inflate very fast and can
rupture. Be prepared to stop the unit quickly when manufacturer’s
recommended inflation pressure is reached.
• Use this compressor with 12 Volt DC systems only.
• Keep the vehicle engine running while the compressor is working.
9
Summary of Contents for 150L
Page 11: ...NOTES 11 ...