Art-Net/DMX Control
Addressing DMX Devices
Your devices receive messages from DeltaServer according to the
DMX Base Address and their
respective Delta channels
.
Each Base Address can be any number within range (0-511) but should be unique for independent
devices: it should not coincide with any other base/channel number unless this is the requirement
(e.g. multiple devices listening to the same part of the addressed block).
Plan your device requirements:
For example,
Light 1
has base address of 1 and can have 4 Delta output channels:
·
Red channel 1 (values 0–255)
·
Blue channel 2 (values 0–255)
·
Green channel 3 (values 0–255)
·
Brightness channel 4 (values 0–255)
Light 2 can then start at base address 5 and take up 4 channels, and so on.
Further instructions for addressing specific devices may be found in its manufacturer’s user
manual.
DIP switch settings
The example below shows a DIP switch chart denoting that this light is ON (switch 10) with a base
address of 5 (switches 1 and 3):
Summary of Contents for DeltaServer