background image

13

WARNING.

 Prior to connecting any product to the generator, 

check the rating label of the product. The generator is rated 

at 650W so if the product being connected is higher than 

650W, the protective cut out on the generator may operate 

to prevent over load damage to the generator. The generator 

will withstand short operation and spikes up to 720W.
It should also be very clearly understood that output voltage 

fluctuations will occur when various loads are connected 

and disconnected. It is best to always use a voltage or surge 

protector with this generator. 

It is NOT recommended to 

connect any electronic equipment to the generator such 

as computers, televisions, or stereo equipment. They 

are very sensitive to the input supply fluctuations and 

could be damaged if run off this generator. This warning 

also includes caravans where electronic equipment is 

incorporated as part of the wiring.

AC overload cut out

IMPORTANT:

 

Exceeding the rated capacity of your 

generator can result in serious damage to your generator 

and connected apparatus.
1. The AC 240V output has a circuit breaker to protect the 

generator from over loading.

2. If the circuit breaker trips, unplug all electrical apparatus 

from the generator.

3. Let the overload cut out switch cool down.
4. If it is an AC apparatus causing the overload push the AC 

circuit breaker button (11).

5. When re connecting appliances, reduce the load to that 

which previously overloaded the generator.

Periodic maintenance

Items

Remarks

Every 50hrs 

or every 

month

Every 150 

hrs or every 

month

Spark Plug Remove 

Carbon

x

Air Filter

Cleaning

x

Fuel Filters Clean

x

Decarbon- 

isation

Clean

x

Generator maintenance

Your generator should be kept clean and dry at all times.  

The generator should not be stored or operated in environments 

that includes excessive moisture, dust or any corrosive vapours. 

If these substances are on the generator, clean with a cloth or 

soft bristle brush. Do not use a garden hose or anything with 

water pressure to clean the generator. Water may enter the 

cooling air slots and could possibly damage the rotor, stator and 

the internal windings of the generator head.

Storage

If you are going to store your generator for more than  

30 days, use the following information as a guide to  

prepare the generator for storage.

Never store generator with fuel in the tank indoors or 

in enclosed, poorly ventilated areas, where fumes can 

reach an open flame, spark or pilot light as on a furnace, 

water heater, clothes dryer or other gas appliances.

Remove all fuel from the fuel tank.
Drain all fuel from the Carburetor bowl.
When storing the generator, ensure the generator has  

fully cooled.

Summary of Contents for A750

Page 1: ...Black Cyan Magenta Yellow Code A750 Date 101125 Edition 03 Op AB INSTRUCTION MANUAL A750 720W GENERATOR ...

Page 2: ... parts 8 Risk from lifting 8 Additional safety rules for generators 9 Unpacking 9 Know your product 10 What can I use this generator for 11 Fitting the handle 11 Mixing the fuel 11 Filling the fuel tank 11 Starting the engine 12 Stopping the engine 12 Connecting apparatus to the generator AC 12 AC overload cut out 13 Periodic maintenance 13 Generator maintenance 13 Storage 13 Spark plugs 14 Air fi...

Page 3: ...park Plugs Bosch W5CC NGK BP5ES CHAMPION N12YC Operation Noise Level 68dB 7m Net Weight 17kg Introduction Your new 909 power tool will more than satisfy your expectations It has been manufactured under stringent 909 Quality Standards to meet superior performance criteria You will find your new tool easy and safe to operate and with proper care it will give you many years of dependable service CAUT...

Page 4: ... it was not intended 7 Dress correctly Do not wear loose clothing or jewellery They can be caught in moving parts Rubber gloves and non slip footwear are recommended when working outdoors If you have long hair wear a protective hair covering 8 Use safety accessories Safety glasses and earmuffs should always be worn A face or dust mask is also required if the drilling operation creates dust 9 Secur...

Page 5: ...ctrical current could charge conductive surfaces in contact with the generator Place generator on low conductivity surface such as a concrete slab ALWAYS operate generator a minimum of 2 meters from any conductive surface Use of worn damaged or ungrounded extension cords Contact with worn or damaged extension cords could result in electrocution Use of ungrounded cordsets could prevent operation of...

Page 6: ...ovide safe operation Tampering with the engine speed adjustment could result in overheating of attachments and could cause a fire Never attempt to speed up the engine to obtain more performance Both the output voltage and frequency will be thrown out of standard by this practice endangering attachments and the user Inadequate ventilation for generator Materials placed against or near the generator...

Page 7: ...o prevent it Gasoline engines produce toxic carbon monoxide exhaust fumes Breathing exhaust fumes will cause serious injury or death Operate generator in clean dry well ventilated area Never operate unit in enclosed areas such as garages basements storage sheds or in any location occupied by humans or animals Keep children pets and others away from area of operating unit Risk of unsafe operation H...

Page 8: ... Hazard What could happen How to prevent it Contact with moving parts can result in serious injury The generator contains parts which rotate at high speed during operation These parts are covered by guarding to prevent injury Never operate generator with guarding or cover plates removed Avoid wearing loose fitting clothing or jewellery which could be caught by moving parts Risk from lifting Hazard...

Page 9: ...ep your distance The generator emits exhaust fumes As a safety precaution do not stand close to the unit whilst it is in operation Ensure bystanders also keep their distance 9 Ensure you use oil mix fuel Ensure that you mix 50 parts unleaded fuel to 1 part 2 stroke grade oil If not mixed correctly at 50 1 the engine will overheat and cause damage to your generator 10 Never fill fuel tank indoors N...

Page 10: ...your product 1 Handle 2 Fuel cap 3 Fuel tank 4 Fuel tap 5 Recoil starter 6 On off switch 7 Choke 8 Air filter cover 9 Tap extension fuel filter 10 AC Output 240V 11 AC circuit breaker 4 5 3 2 1 6 7 8 10 4 9 11 ...

Page 11: ... fitted under the heads of the screws Mixing the fuel 1 The generator uses unleaded fuel and 2 stroke grade oil Note Ethanol unleaded fuel is NOT recommended 2 You need to mix both unleaded fuel and 2 stroke oil together 3 The proportion should be 50 parts unleaded fuel and 1 part 2 stroke oil Quick reference common fuel mixture requirements for 50 1 is 1 Litre of unleaded fuel mixed with 20mL of ...

Page 12: ...engine has been operating for 10 15 seconds slowly return the choke lever back to the right hand side position This position will switch the choke off Note If the generator stops move the choke back to the full left hand side and repeat the starting operation Stopping the engine 1 Before stopping ensure that no electrical apparatus is connected to the generator 2 Press O on the engine switch 6 to ...

Page 13: ...t the overload cut out switch cool down 4 If it is an AC apparatus causing the overload push the AC circuit breaker button 11 5 When re connecting appliances reduce the load to that which previously overloaded the generator Periodic maintenance Items Remarks Every 50hrs or every month Every 150 hrs or every month Spark Plug Remove Carbon x Air Filter Cleaning x Fuel Filters Clean x Decarbon isatio...

Page 14: ... air filter element in place Tap extension fuel filter A small fuel filter has been fitted to the inlet side of the fuel tap 4 inside the tank This tap extension fuel filter 9 prevents any dirt in the fuel from entering the fuel system The procedure for removing this filter in order to replace or clean it is given below Note the following procedure should be performed in a well ventilated area wit...

Page 15: ...the tank with fuel and ensure there are no leaks between the tap and the tank and with the fuel tap turned on ensure there are no leaks where the fuel hose is fitted to the outlet of the tap Petrol tank filter 1 Stop the engine 2 Turn the fuel tap 4 to the off position 3 The petrol tank filter is located directly under the petrol cap This protects impurities entering the fuel tank during refuellin...

Page 16: ...ark plug wire loose 7 Attach wire to spark plug 8 Dirty fuel filters 8 Clean filters as per instructions No electrical output 1 Faulty receptacle 1 Have service centre replace receptacle 2 Circuit breaker kicked out 2 Depress and reset 3 Defective capacitor 3 Have service centre replace capacitor 4 Faulty power cord 4 Replace cord Repeated circuit breaker tripping 1 Overload 1 Reduce load 2 Faulty...

Page 17: ......