Step 7 – Testing Basic S4 Operations (continued)
Now the Installer can turn Off vehicle ignition and trigger the
vehicle alarm (or keyfob “Panic”) for at least 8 sec. The
S4 can be programmed by SMS to detect an alarm signal
that is either high (12v) or low (0 v). When S4 receives
the correct high or low alarm output signal, Installer will
receive an Alarm Sounding text notification. This confirms
that the alarm connection is proper.
If terminal 7 goes to
12v for alarm
, Installer needs to send:
12345 at*alarm=1
(note space after PIN).
12345 at*alarm=0
changes the
alarm detection from high to low (note space after PIN).
If Out #1 has been connected, the Installer should check by
sending:
12345 relay on
(note space after PIN and space
after relay). The S4 will turn on the relay and the starter
will be disabled. Then the Installer should send:
12345
relay off
(note space after PIN and space after relay).
The S4 will turn the relay off and the starter will function
normally.
If Out #2 has been connected, the Installer should check by
sending:
12345 pulse
(note space after PIN). The S4 will
cause Out #2 to pulse for 1 second, which should activate
that function (door unlock, door lock, flash headlights,
sound horn, etc.) that was chosen by the Owner.
Now the Installer should send:
12345 at*user=0,OwnerMobileNumber,1
(note space
after PIN). This sets the Owner’s number in the S4.
Installation is now complete.
14