background image

 

 

 

 

Hydraulic circuit 

 

 
Electrical features 
The pump is controlled by a relay with a 10-Amp contact, whereas the solenoid valve is controlled by a relay with an 8 
amp contact. 
The high/voltage connections of the volumetric meters and the level probe are made with 6.38mm faston connectors, 
whereas  the  connections  to  the  push  button  panels  and  the  serial  transmission  are  made  with  model  II  AMP 
connectors. 
All of the components are UL/VDE/CSA approved. 
The  control  unit  is  built  to  standard  CEI  61-150  (European  Standard  EN  60  335-1)  on  safety  of  household  and  similar 
electrical appliances. 
The  operating  room  temperature  range  is  between  0°C  (32°F)  and  70°C  (158°F).La  temperatura  ambiente  di 
funzionamento è compresa tra 0°C e 70°C. 
 

Summary of Contents for Globus Series

Page 1: ...Serie Globus...

Page 2: ...for its intended purpose i e for making coffee Any other use is incorrect and therefore dangerous After removing the machine from its package make sure that it has not been damaged during transport an...

Page 3: ...ch button panel only electronic version 11 Pressure gauge 12 0 1 switch 13 Hot water switch 14 Manual filling 4 Technical Features GLOBUS GROUPS 1 2 compact 2 3 WIDTH 500 580 700 900 DEPTH 520 520 520...

Page 4: ...38mm faston connectors whereas the connections to the push button panels and the serial transmission are made with model II AMP connectors All of the components are UL VDE CSA approved The control uni...

Page 5: ...intenance operations Place the water drain and the electrical and hydraulic connections max 1 meter from the worktop WARNING The machine is designed for indoor installation Therefore it should not be...

Page 6: ...9 atm 132 psi If it does adjust the pump fitted on the back of the machine on the right Use Before each use or if the coffee maker does not work make sure that the power cord is plugged in and mains p...

Page 7: ...ess the desired selection button Fig 13 The corresponding LED turns on The machine will automatically stop when the preset amount has been dispensed To interrupt the brewing process at any time press...

Page 8: ...ds must also be cleaned by using a sponge and hot water Troubleshooting If all the LEDS flash at the same time the control unit is signaling a problem The most important cases include pu p ru i g ti e...