Periodic controls
On a regular basis, i.e. every 15/20 Kg of coffee, remember to clean the water softener system in order to remove any
calcium salts deposited inside (see the related manual)
Cleaning
To ensure both trouble-free operation of this machine and great-tasting coffee, the machine must be cleaned properly
We recommend repeating the operations below at least once a day and/or after long idle periods!
WARNING!
Turn off the machine and unplug it before carrying out any cleaning operations!
To clean the machine, do not use water jets or immerge it in water!
Do not use solvents, abrasive powders, or steel wool.
Outside
After having dispensed the last coffee, clean the filter baskets and filter holders (Fig. 14) with boiling water, detergent,
and the special brush.
Remove the grid and drip tray (Fig. 15) and use hot water and a sponge to eliminate any residue.
Also clean the external body with a sponge or soft cloth and liquid detergent.
Ducts
If the filter is clogged or deteriorated, contact the after-sales service center for its replacement.
The group shower heads and wands must also be cleaned by using a sponge and hot water.
Troubleshooting
If all the LEDS flash at the same time, the control unit is signaling a problem.
The most important cases include:
• pu p ru i g ti
e has exceeded 2 minutes while filling the boiler. This is usually due to:
-
no water arriving;
-
the level regulator malfunctioning
• Water does ot flo duri g dispe si g for ore tha 3 se o ds. This is usuall due to:
-
no water in the hydraulic circuit
-
clogged jet;
-
faulty volumetric meter
-
unsuitable grinding (too fine)
Turn off the machine. Do not attempt to repair
Filling the boiler
A probe located inside the boiler controls the water level.
Based on the water level, the pump will turn on and off but only after a certain delay in order to prevent continuous
operations due to the oscillation of water level.
Machine failure
Contact the technical assistance center.
Accessories
The machine is supplied with a filling tube and drainage tube with relative clamps, blind filter and brush for daily
cleaning, together with filter holders and filters.
Warranty
The warranty expired after 12 months from the purchasing date. It covers the mechanical parts and includes the spare
parts.
It shall be null and void if the machine is improperly used or unauthorized personnel have tampered with it.
Summary of Contents for Globus Series
Page 1: ...Serie Globus...