background image

©

2005 A+ Corporation, LLC.  All rights reserved.

SCC-38M-InsInstallationOperation_100318

An ISO 9001:2008 certified company 

Manufacturing   Contact   Information

A+ Corporation, LLC

41041 Black Bayou Rd.
Gonzales, LA   70737

Call for expert product application assistance:

Phone: (225)-644-5255  Website: www.geniefilters.com
Fax:  (225)-644-3975  E-mail: sales@geniefilters.com

Safety Warnings

!

Tools Required

Avenger™ Model 38M 

Installation & Operation Instructions

Failure to abide by any of the safety warnings below may result in equipment failure and serious injury or death.

 

}

For models containing Liquid Block™: Slowly open the supply pressure so that the minimum differential pressure required to                       

shut-off the Liquid Block™ is not met or exceeded..

 

}

Valve off the sample flow before installation.

 

}

Do not exceed any equipment pressure 

 

}

Four #10 screws for mounting bracket to panel.

 

}

Screwdriver for mounting bracket to panel.

Summary of Contents for Avenger 38M

Page 1: ...ers com Safety Warnings Tools Required Avenger Model 38M Installation Operation Instructions Failure to abide by any of the safety warnings below may result in equipment failure and serious injury or death For models containing Liquid Block Slowly open the supply pressure so that the minimum differential pressure required to shut off the Liquid Block is not met or exceeded Valve off the sample flo...

Page 2: ...ned parts 316 316L stainless steel NACE compliant All other metal parts stainless steel NACE compliant Sealing material Fluoroelastomer standard Membrane inert 2 000 psig 1 4 female NPT 185 F 85 C for Type 6 membrane 302 F 150 C for Type 7 membrane 1 000 cc min for Type 6 membrane 3 600 cc min for Type 7 membrane Maximum flow results in approximately 2 psi membrane differential pressure Maximum re...

Page 3: ...Model 38M Aftermarket brackets may be mounted as per the mounting diagrams below Mount the Avenger horizontally as shown in the diagram Lock washers may be used on the lower 10 32 screws to tilt the filter as shown to ensure that liquids drain properly Port D should be facing down as shown An optional downstream pressure gauge may be installed in Port E or it may be plugged The Model 33M has 1 2 N...

Page 4: ... 2005 A Corporation LLC All rights reserved SCC 38M InsInstallationOperation_100318 An ISO 9001 2008 certified company 4 Application Drawing ...

Page 5: ...ids from vapor 7 Rejects ONLY high surface tension liquids Liquid Block Blank No Liquid Block L Liquid Block Mounting bracket accessory Part 38 509SS sold separately 38M 3 2 S Sealing material Element type Membrane type Liquid Block option Liquid Block option Liquid Block option 30 5 5 Element type Membrane type 38M 5 0 38M 5 0 Sealing material S L S Replacement filter and membrane kits contain 5 ...