background image

An ISO 9001:2008 certified company 

Genie,    

®

 Avenger,

TM

 Liquid Block

TM

 and Genie

®

 Membrane Technology

TM 

are trademarks or registered 

trademarks of A

+

 Corporation, LLC.  All other referenced trademarks are the property of their respective owners. 

Model Numbering & Additional Part Numbers

Model Numbering & Additional Part Numbers

How to build the model number:

How to build the replacement filter element number:

How to build the replacement membrane kit number:

How to build the replacement o-ring kit number:

Your model number is determined by your specific needs. Choose options below.

Sealing material

 

0 =  Fluoroelastomer 

1 = Perfluoroelastomer

 

(other materials available upon request)

Element type

 

07CFS = 0.1 micron coalescer fluorocarbon

  

SS10 = 10 micron stainless steel 

 

Membrane type

 

6 = Rejects ALL types of liquids from vapor                  7=  Rejects ONLY high surface tension liquids

 

 

Liquid Block™

 

Blank = No Liquid Block

 

L = Liquid Block

Mounting bracket accessory

 Part # 38-509SS 

(sold separately)

38M

3/2

 S 

Sealing material

Element type

Membrane type
Liquid Block

 option

Liquid Block

 option

Liquid Block

 option

30

5

 5 

Element type

Membrane type

38M

5

0

38M

 5

 

Sealing material

S

L

S

Replacement filter and membrane kits contain 5 each. O-ring replacement kit contains all assembly o-rings.

We cannot recommend specific sealing materials due to the complex nature of sample stream compositions. Temperature and pressure also may be factors.  Unless specified otherwise, the product 
will ship with our standard sealing materials and materials of construction stated in the technical specifications section of the corresponding Product Sheet.
Please refer to dupontelastomers.com for sealing material recommendations and advice. It is the user’s responsibility to specify the sealing materials of construction for their application. 

Summary of Contents for Avenger 38M

Page 1: ...ers com Safety Warnings Tools Required Avenger Model 38M Installation Operation Instructions Failure to abide by any of the safety warnings below may result in equipment failure and serious injury or death For models containing Liquid Block Slowly open the supply pressure so that the minimum differential pressure required to shut off the Liquid Block is not met or exceeded Valve off the sample flo...

Page 2: ...ned parts 316 316L stainless steel NACE compliant All other metal parts stainless steel NACE compliant Sealing material Fluoroelastomer standard Membrane inert 2 000 psig 1 4 female NPT 185 F 85 C for Type 6 membrane 302 F 150 C for Type 7 membrane 1 000 cc min for Type 6 membrane 3 600 cc min for Type 7 membrane Maximum flow results in approximately 2 psi membrane differential pressure Maximum re...

Page 3: ...Model 38M Aftermarket brackets may be mounted as per the mounting diagrams below Mount the Avenger horizontally as shown in the diagram Lock washers may be used on the lower 10 32 screws to tilt the filter as shown to ensure that liquids drain properly Port D should be facing down as shown An optional downstream pressure gauge may be installed in Port E or it may be plugged The Model 33M has 1 2 N...

Page 4: ... 2005 A Corporation LLC All rights reserved SCC 38M InsInstallationOperation_100318 An ISO 9001 2008 certified company 4 Application Drawing ...

Page 5: ...ids from vapor 7 Rejects ONLY high surface tension liquids Liquid Block Blank No Liquid Block L Liquid Block Mounting bracket accessory Part 38 509SS sold separately 38M 3 2 S Sealing material Element type Membrane type Liquid Block option Liquid Block option Liquid Block option 30 5 5 Element type Membrane type 38M 5 0 38M 5 0 Sealing material S L S Replacement filter and membrane kits contain 5 ...