UNIVERSAL TOASTER UTX-200
15
P/N 1010904 Rev. 14 04/06
McDonald’s
TROUBLESHOOTING
Problem
Possible Cause
Corrective Action
No Display and/or no light on the
Rocker Switch (power On/Off)
Unit not plugged in.
Plug the power cord into the appro-
priate outlet.
Hi-Limit thermostat is tripped.
Reset Hi-Limit.
Circuit Breaker tripped
Reset Circuit Breaker.
Power Cord and/or plug are dam-
aged.
Contact your maintenance person or
Authorized Service Agency.
Inoperable Rocker Switch (power
On/Off).
Unit displays one of the following
messages:
Upper IR Heater Fault
or
Lower IR Heater Fault
Failed heater
Allow about 10 minutes for the toast-
er to self adjust.
Wire disconnected in IR circuit
Control wires to the Solid State
Relay are disconnected
Adjust the toast quality setting. Refer
to the Operation section of this
manual.
The Solid State Relay has failed
Unit displays the following message:
Conveyor Motor Fault
Product is getting stuck in the con-
veyor system or the conveyor sys-
tem is jammed.
Check and clear the vertical and
horizontal conveyors for any stuck
product. Refer to the Operation and
Maintenance sections of this manual
for proper compression settings and
cleaning procedures.
The motor controller circuit has
failed or is inoperable.
Call your Authorized Service Agency
for service.
The unit displays the following mes-
sage:
SSR Failure - System Stopped
A relay has failed preventing proper
heater control
The toaster cannot be operated with
this kind of failure. Contact your
Authorized Service Agency for ser-
vice.
The unit displays the following mes-
sage:
Platen Temp Fault
A heater or relay in the Platen cir-
cuit has failed.
The conveyors will continually adjust
speed to compensate for low Platen
temperature. If the Platen cannot
maintain 525º F, the unit will signal
an error and stop operating. If this
happens, contact your Authorized
Service Agency for service.
CAUTION
To avoid possible personal injury and/or damage to the unit, all inspections, tests, and repair of electrical
equipment should be performed by QUALIFIED SERVICE PERSONNEL. The unit MUST be completely shut
down and unplugged before servicing, except when electrical tests are required. Use extreme care during
electrical circuit tests. Live circuits will be exposed.