! The appliance must be installed by a qualified
person in compliance with the instructions
provided.
Wear gloves when carrying out installation and
maintenance operations.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Warning: Failure to install the screws or fixing device in
accordance with these instructions may result in
electrical hazards.
AIR VENT
(for ducting versions)
! Prepare the hole and the air vent duct (150 mm
diameter).
! Use a duct of the minimum indispensible length.
! Use a duct with as few elbows as possible (maximum
elbow angle: 90°).
! Avoid drastic changes in the duct cross-section.
! Use a duct with an as smooth as possible inside.
! The duct must be made of certified material.
! Do not connect the hood to smoke exhaust ducts for
the products of combustion (boilers, fireplaces,
stoves, etc).
! For the air vents comply with the provisions laid down
by the competent authorities.
In addition, the air must not be evacuated through a
hole in the wall unless specifically intended for this
purpose.
! Fit air intakes in the room to prevent the hood from
creating a negative pressure in the room (which must
not exceed 0.04 mbar); if the hood is used at the
same time as non-electrical equipment (gas-, oil- and
charcoal-fired stoves, etc.) the exhaust gas may be
sucked in by the heat source.
FILTERING OR DUCTING VERSION ?
The hood may be in filtering or in ducting version.
Decide from the outset which type is to be installed.
For better efficiency, we recommend installing the hood
in the ducting version (if possible).
Ducting version
Versione with external motor
The hood purifies the air and evacuates it to the outside
through an exhaust duct (diameter 150 mm).
Filtering version
The hood purifies the air and recycles the clean air
back into the room.
Only for hoods equipped with electronic control:
The 4th speed (intensive) is automatically lowered to
3rd speed after 5 minutes of operation to optimise energy
consumption; in hoods with voltage 120V/60Hz this
function is not active and the 4th speed is indicated by
the letter b (Booster).
- If the hood is left on (lights and/or motor), after 10
hours in the absence of commands from the user, it will
automatically switch to OFF condition with all services
switched off. In hoods with voltage 120V/60Hz this
function is not active.
- The Buzzer emits a “beep” each time that a command
is set from the keyboard or remote control (optional).
- In the event of interruption of power during the hood,
if you restore the hood in the OFF state, then the
engine must be reactivate manually.
Only for hoods equipped with infrared sensor
controls: The unit is equipped with infrared sensor
controls that, if exposed to direct sunlight may not work
properly; use curtains or other devices to shield the
sunlight.
CONTROLS
Controls
Key A: light switch.
Key B: first speed motor ON/OFF switch.
Key C: second speed switch.
Key D: third speed switch.
Controls
Button TC1 (Lights): Switches main light ON/OFFWhen
the main light is on, BL1 changes colour and becomes
active.When the button is pressed for more than a
second, it switches the courtesy lights (optional) on/off.
Button TC2 (Motor-V1): Motor ON/OFF - Activates the
motor at 1st speed.
Button TC3 (Motor-V2)Activates the motor at 2nd
speed.
Button TC4 (Motor-V3)Activates the motor at 3rd speed.
Button TC5 (Motor-V4)Activates the motor at 4th
speedMaximum speed is timed at a maximum of 5
minutes, after which 3rd speed is set
automatically.When the motor is active, the LED of the
last selected button (TC2-TC5) active to signal which
speed has been set.
Button TC6 (TIMER auto power off 5 min.)Activates the
TIMER function at the speed that has already been
selectedIf the motor is NOT active, it switches on the
motor at the 1st speed and activates the TIMER
functionWhen the TIMER function is active, BL6
becomes active.
30h filter ALARM: after 30 hours of operation, an alarm
switches on to signal the need for anti-grease filter
cleaning.The filter alarm, when active, is displayed for
30 sec each time the motor is deactiva-ted:BL6 remains
A
B
C
D
TC1 TC2
TC3 TC4
TC5
TC6
Summary of Contents for GHOST
Page 2: ...MOD A MOD B C D E F ...
Page 5: ...MOD E MOD A B C D E F MOD F Ø 150 mm ...
Page 6: ...MOD A MOD A B C D E F MOD A Ø 150 mm Ø 150 mm Ø 150 mm ...
Page 7: ...MOD A B C D E F MOD A B C D E F MOD A MOD A MOD A MOD A ...
Page 8: ...MOD A MOD A MOD A MOD A MOD A MOD A ...
Page 9: ...MOD A MOD A MOD A MOD A MOD A MOD A ...
Page 10: ...MOD A B C D E F MOD A B C D E F MOD A B C D E F MOD A B C D E F 21 MOD A 22 ...
Page 11: ...MOD B C D E F 23 24 MOD A ...
Page 56: ...04308399 7 ...