6
DIMENSIONS AND CAPACITIES DATA
Table 1. Tank Capacities and Dimensions
Model Number
Tank Capacity in Gallons (Liters)
A - Inches (mm)
B - Inches (mm)
C - Inches (mm)
Inlet/Outlet
52
50 (189.3)
55 3/4 (1416)
21 3/4 (552)
27 (685)
1 1/4
80
80 (302.8)
60 1/4 (1350)
25 1/2 (648)
31 (787)
1 1/4
120
119 (450.5)
62 1/4 (1581)
29 1/2 (749)
35 (889)
1 1/4
Table 2.
Recovery Rate in Gallons Per Hour Temperature Rise °F
Standard
KW Input
BTU/
Hour
30°
40°
50°
60°
70°
80°
90°
100°
110°
120°
130°
140°
6
20,478
82
62
49
41
35
31
27
25
22
21
19
18
9
30,717
123
92
74
62
53
46
41
37
34
31
28
26
12
40,956
164
123
98
82
70
61
55
49
45
41
38
35
13.5
46,075
184
138
111
92
79
69
62
55
50
46
43
40
15
51,195
205
154
123
102
88
77
68
61
56
51
47
44
18
61,434
246
184
148
123
105
92
82
74
67
61
57
53
24
81,912
328
246
197
164
140
123
109
98
89
82
76
70
27
92,151
369
276
221
184
158
138
123
111
101
92
85
79
30
102,390
410
307
246
205
176
154
137
123
112
102
95
88
36
122,868
492
369
295
246
211
184
164
148
134
123
113
105
40.5
138,226
554
418
3332
277
237
208
1185
166
151
138
128
119
45
153,585
615
461
369
307
263
230
205
184
168
154
142
132
54
184,302
738
553
443
369
316
277
246
221
201
184
170
158
*Figured at 1 KW (3413 Btu) = 4.1 gallons at 100°F temperature rise.
To determine recovery rate per minute, divide recovery rate per hour by 60.
This Instruction Manual covers two models of commercial
electric water heaters:
These two models are equipped from the factory with different
controls.
In this Instruction Manual, one model is factory equipped with
a surface mounted thermostat/ECO combination control and is
referred to as a
surface-mount control
model.
The other model is equipped with an electronic control system
and is referred to as an
electronic control model
.
Figure 1. Dimensions and Components
3/4” NPT
OPENING
DISPLAY FOR
ELECTRONIC
CONTROL
MODELS ONLY
WATER
OUTLET
CONDUIT
OPENING
INLET
OPENING
DRAIN
VALVE
A
C
B
5.25