1) INTRODUCTION

Thank you for purchasing this water heater.

Properly

installed and maintained, it will provide years of trouble free
service.

The warranty on this water heater is in effect only when the
water heater is installed and operated in accordance with
these instructions. The manufacturer of this water heater
will not be liable for any injury or property damage resulting
from failure to comply with these instructions.

II) SAFETY

Relief Valve Requirements

Caution:

To reduce the risk of excessive pressures and

temperatures in this water heater, install temperature and
pressure protective equipment required by local codes. It
should be no less than a combination temperature and

pressure relief valve certified by a nationally recognized
testing laboratory that maintains periodic inspection of pro-
duction of listed equipment or materials, as meeting the lat-
est edition of

“Relief Valves for Hot Water Supply

Systems”, CSA 4.4 

in Canada, “

Relief Valves and

Automatic Gas Shutoff Devices for Hot Water Supply
Systems”, ANSI Z21.22

in the U.S.A. This valve must be

marked with a maximum set pressure not to exceed the
marked MAXIMUM working pressure of the water heater
(150 psi). Install the valve into an opening provided and
marked for this purpose in the water heater, and orient it or
provide tubing so that any discharge from the valve will exit
only within 150mm (6 in.) above, or at any distance below
the structural floor and cannot contact any live electrical
part. The discharge opening must not be blocked or
reduced in size under any circumstances. The end of the
relief pipe opening should terminate near a floor drain or
other suitable location not subject to blocking or freezing.

DO NOT

thread, plug or cap the relief pipe opening.

III) INSTALLATION

Plumbing

1.

The cold water inlet is identified at the top of the heater
(unless bottom entry). The hot water connection is also
identified at the top of the heater. Install a shut-off valve
in the cold line approximately 1m (3 ft.) from the inlet to
the heater where it is in convenient reach. This valve is
for emergency shut-off and MUST be kept open during
the operation of the heater.

2.

The water connection fittings contain a plastic lining to
minimize corrosion and some models include plastic
heat traps. Do not apply heat to these nipples when
making solder connections. Sweat a piece of tubing to
adapter before fitting adapter to nipple.

3.

After installing the water piping, cover with the pipe
insulation (if supplied with this heater). Use the insula-
tion to cover 610mm (2 ft.) of hot and cold piping near-
est to the heater.

4.

A combination Temperature and Pressure relief valve
MUST be installed. In some cases it is necessary that a
Tee be fitted in the top of the heater that allows the tem-
perature probe to reach into the top of the tank (see
Figure 4). No shut-off valve of any kind is permitted
between the tank and the relief valve. The relief valve
discharge line must be piped to a drain or fixture, and
must terminate a maximum of 300mm (12 in.) (Canada)
or 150mm (6 in.) (U.S.A.) from the floor.

– 3 –

WARNING

Failure to install a listed 3/4" Temperature &
Pressure Relief Valve will release the
Manufacturer from any claim that might
result from excessive temperatures and
pressures.

CAUTION

Hydrogen gas can be produced in a hot water system
served by this storage tank that has not been used for a
long period of time (generally two (2) weeks or more).

Hydrogen gas is extremely flammable and can ignite
when exposed to a spark or flame.

To reduce the risk of

injury under these conditions, it is recommended that the
hot water faucet be opened for several minutes at the
kitchen sink before using any electrical appliance con-
nected to the hot water system. Use caution in opening
faucets. If hydrogen is present, there will probably be an
unusual sound such as air escaping through the pipe as
the water begins to flow. There should be no smoking or
open flame near the faucet at the time it is open.

IMPORTANT:

This water heater must be installed strictly in accordance
with the instructions enclosed, and local electrical, fuel
and building codes. It is possible that connections to the
water heater, or the water heater itself, may develop
leaks. IT IS THEREFORE IMPERATIVE that the water
heater be installed so that any leakage of the tank or relat-
ed water piping is directed to an adequate drain in such a
manner that it cannot damage the building, furniture, floor
covering, adjacent areas, lower floors of the structure or
other property subject to water damage. This is particular-
ly important if the water heater is installed in a multi-story
building, on finished flooring or carpeted surfaces. THE
MANUFACTURER WILL NOT ASSUME ANY LIABILITY
for damage caused by water leaking from the water
heater, pressure relief valve, or related fittings. Select a
location as centralized within the piping system as possi-
ble. In any location selected, it is recommended that a
suitable drain pan be installed under the water heater.
This pan must limit the water level to a MAXIMUM depth
of 45mm (1 3/4 in.) and have a diameter that is a minimum
of 50mm (2 in.) greater than the diameter of the water
heater. Suitable piping shall connect the drain pan to a
properly operating floor drain. When used with a fuel-fired
heater, this drain pan must not restrict combustion air flow.

Summary of Contents for 324419-000

Page 1: ...ING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage per sonal injury or death WARNING Improper installation adjustment alter ati...

Page 2: ...2 This page intentionally left blank May be used for notes or to record other installation information...

Page 3: ...piping near est to the heater 4 A combination Temperature and Pressure relief valve MUST be installed In some cases it is necessary that a Tee be fitted in the top of the heater that allows the tem pe...

Page 4: ...s The ther mostat will direct the second leg of the 120 volts to the ele ment to complete the 240 volts required for energizing the element Initial Start Up When the tank is full of cold water the upp...

Page 5: ...Check with a voltage tester at terminal 1 and 3 of the limit control that power is indeed OFF 4 Adjust the thermostat s to the water temperature desired if a two thermostat system exists set both ther...

Page 6: ...which can have significant effect on the life of your heater Water conditioning such as over softening can accelerate the rate at which the anode rod is consumed Rapid depletion can leave a heater unp...

Page 7: ...cian Water Is Too Hot Adjust the thermostats to a lower setting See Temperature Adjustment section It is imperative that the thermostat is flush against the tank See Thermostat Replacement sec tion Ho...

Page 8: ...eleases about one cup of water for every 10 gallons of heater capacity with each heating cycle The T P valve is functioning properly when it relieves pressure caused by thermal expansion but frequent...

Page 9: ...trated 8 Thermostat 9 Drain valve 10 Water supply to meter 11 Water supply to water heater 12 Water meter with backflow preventer 13 Overflow 14 Pressure relief valve 15 Expansion tank 16 Pipe Insulat...

Page 10: ...10 599 Hill Street West Fergus ON Canada N1M 2X1 PHONE 1 888 479 8324 www hotwatercanada ca email techsupport hotwater com...

Reviews: