background image

– 9 –

OPTION 2

OPTION 1

A

bent tube (as

shown) is installed for
the hot water outlet on
side outlet water
heaters to ensure a
maximum of hot water
supply. This fitting
must be aligned prop-
erly. The 'line' on the
fitting must be orient-
ed pointing up. When
in correct position, the
hot water is drawn
from the highest point
in the tank.

SPACESAVER™ MODELS 

(SIDE OUTLET) ONLY

NOTE TO INSTALLERS:

1.

Cold water inlet

2.

Hot water outlet

3.

Anode(s)

4.

Temperature and pressure (T&P) relief valve*

4a. Alternate location of T&P relief valve*
5.

Thermostat with High-limit switch

6.

Element

7.

Access door - not illustrated

8.

Thermostat

9.

Drain valve

10. Water supply to meter
11. Water supply to water heater
12. Water meter with backflow preventer
13. Overflow
14. Pressure relief valve
15. Expansion tank
16. Pipe Insulation (mandatory if supplied with heater)
*Items to be supplied by installer.

Options 1 and 2 show the location of pressure relief and/or
expansion tank if a check valve or pressure reducing valve
is in the cold water supply to the house. Use option 1 or 2
as convenient. If a pressure relief valve is used (OPTION 1)
select one with a setting 25 psi below the relief valve rating
used on the heater.

Drain pan*

Floor drain

Floor drain

Tee fitting

Refer to pressure
relief/expansion tank
schematic above.

Floor Drain

Drain pan*

Drain valve*

Cold in

Hot out

Cold in

Hot out

Figure 4

Parts Reference

Summary of Contents for 324419-000

Page 1: ...ING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage per sonal injury or death WARNING Improper installation adjustment alter ati...

Page 2: ...2 This page intentionally left blank May be used for notes or to record other installation information...

Page 3: ...piping near est to the heater 4 A combination Temperature and Pressure relief valve MUST be installed In some cases it is necessary that a Tee be fitted in the top of the heater that allows the tem pe...

Page 4: ...s The ther mostat will direct the second leg of the 120 volts to the ele ment to complete the 240 volts required for energizing the element Initial Start Up When the tank is full of cold water the upp...

Page 5: ...Check with a voltage tester at terminal 1 and 3 of the limit control that power is indeed OFF 4 Adjust the thermostat s to the water temperature desired if a two thermostat system exists set both ther...

Page 6: ...which can have significant effect on the life of your heater Water conditioning such as over softening can accelerate the rate at which the anode rod is consumed Rapid depletion can leave a heater unp...

Page 7: ...cian Water Is Too Hot Adjust the thermostats to a lower setting See Temperature Adjustment section It is imperative that the thermostat is flush against the tank See Thermostat Replacement sec tion Ho...

Page 8: ...eleases about one cup of water for every 10 gallons of heater capacity with each heating cycle The T P valve is functioning properly when it relieves pressure caused by thermal expansion but frequent...

Page 9: ...trated 8 Thermostat 9 Drain valve 10 Water supply to meter 11 Water supply to water heater 12 Water meter with backflow preventer 13 Overflow 14 Pressure relief valve 15 Expansion tank 16 Pipe Insulat...

Page 10: ...10 599 Hill Street West Fergus ON Canada N1M 2X1 PHONE 1 888 479 8324 www hotwatercanada ca email techsupport hotwater com...