7
TABLE 3. RECOVERY CAPACITIES
MODELS
TYPE OF
GAS
INPUT
°F
20
40
50
60
70
80
BTU/HR
KW
°C
(11)
(22)
(28)
(33)
(39)
(44)
HW 300
Natural
300,000
88
GPH
1,455
727
582
485
416
364
Propane
LPH
5,506
2,753
2,202
1,835
1,573
1,377
HW 399
Natural
399,000
117
GPH
1,935
967
774
645
553
484
Propane
LPH
7,323
3,662
2,929
2,441
2,092
1,831
HW 420
Natural
420,000
123
GPH
2,036
1,018
815
679
582
509
Propane
LPH
7,708
3,854
3,083
2,569
2,202
1,927
HW 520
Natural
520,000
152
GPH
2,521
1,261
1,008
840
720
630
Propane
LPH
9,544
4,772
3,818
3,181
2,727
2,386
HW 670
Natural
660,000
193
GPH
3,200
1,600
1,280
1,067
914
800
LPH
12,113
6,057
4,845
4,038
3,461
3,028
HW 670
Propane
670,000
196
GPH
3,248
1,624
1,299
1,083
928
812
LPH
12,297
6,148
4,919
4,099
3,513
3,074
ELECTRICAL REQUIREMENTS
MODELS SUPPLY VOLTAGE
(VOLTS)
FREQUENCY
(HZ)
CURRENT
(AMPS)
HW 300
120
60
12
HW 399
120
60
12
HW 420
120
60
12
HW 520
120
60
12
HW 670
120
60
12
TABLE 4. ELECTRICAL REQUIREMENTS